Lenovo x3100 M5 Product Manual

Hide thumbs Also See for x3100 M5:

Advertisement

Quick Links

System x3100 M5
Lenovo Press Product Guide
The System x3100 M5 single-socket tower server is designed for small businesses and first-time server
buyers looking for a solution to improve business efficiency. It delivers several innovative features with a
competitive price, either in a compact mini-tower form factor, or standard tower form factor with hot-swap
power supplies and disk drives. The System x3100 M5 provides next-generation performance in an
innovative and compact design with flexible configuration options, built-in security, and systems
management capabilities. It leverages the next-generation dual-core and quad-core Intel Xeon processor
technology.
Suggested uses: Retail/kiosks, and SMBs, looking for file and printer servers, web serving, small
business infrastructure, and virtual desktops for small workgroups.
Figure 1. The System x3100 M5 (compact mini-tower shown)
Did you know?
The System x3100 M5 server is a compact, cost-effective, single-processor tower or rack-mountable
server that has been optimized to provide outstanding availability, manageability, and performance
features to small-to-medium-sized businesses, retail stores, or distributed enterprises. It supports the
Intel Xeon E3-1200 v3 "Haswell" family of processors for applications that require performance and
stability, and Core i3, Pentium, and Celeron processors for applications that require lower cost.
The system includes features that are not typically seen in this class of system, such as standard,
embedded RAID 0 and RAID 1, remote control capabilities even when the machine is powered off, and
Predictive Failure Analysis (PFA) on processor and memory. Some models also support hot-swap
redundant power supplies and hot-swap disk drives.
System x3100 M5
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo x3100 M5

  • Page 1 System x3100 M5 Lenovo Press Product Guide The System x3100 M5 single-socket tower server is designed for small businesses and first-time server buyers looking for a solution to improve business efficiency. It delivers several innovative features with a competitive price, either in a compact mini-tower form factor, or standard tower form factor with hot-swap power supplies and disk drives.
  • Page 2: Key Features

    You need to squeeze as much as possible out of your IT dollars while saving costs on features that are not needed in an SMB environment. The System x3100 M5 is an ideal first server to meet those business needs. It was built for speed, yet eliminates costly design features that are found in general-purpose servers that are unnecessary for smaller businesses.
  • Page 3 Energy efficiency The x3100 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment: Energy-efficient planar components help lower operational costs.
  • Page 4: Locations Of Key Components

    Locations of key components The x3100 M5 is available in two different tower designs: a compact tower with a fixed power supply and simple-swap drive bays, or a standard tower with hot-swap power supplies and hot-swap drive bays. Figures 2 and 3 show the front and rear of the x3100 M5.
  • Page 5 Figures 4 and 5 show the locations of key components inside the server. Figure 4. Inside view of System x3100 M5 - compact tower configuration Figure 5. Inside view of System x3100 M5 - standard tower configuration System x3100 M5...
  • Page 6: Standard Specifications

    (model specific). Tape drive bays One 5.25" HH bay, support for DDS, RDX, or LTO drive. Network interfaces Integrated two-port Gigabit Ethernet (Broadcom BCM5717). One port is shared with the Integrated Management Module (IMM). System x3100 M5...
  • Page 7 Compact tower: Minimum configuration: 10 kg (22.0 lb), maximum: 13 kg (28.7 lb) Standard tower: Minimum configuration: 19.6 kg (43 lb), maximum: 22 kg (48.5 lb) The x3100 M5 servers are shipped with the following items: Statement of Limited Warranty.
  • Page 8: Standard Models

    Multi- 1x 430W 2 / 2 8MB 1600MHz 4C (80W) 1600 MHz M1115 burner hot-swap * Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, memory speed, and thermal design power (TDP) rating System x3100 M5...
  • Page 9: Express Models

    * Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, memory speed, and thermal design power (TDP) rating † Model EKx includes ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for System x (81Y4487) and System x3100 Hardware RAID Remote Battery/Cap Mechanical kit (00J6455) System x3100 M5...
  • Page 10: Processor Options

    The following table lists all processors that are available in standard models of x3100 M5 or through configure-to-order (CTO). If there is no corresponding where-used model for a particular processor, then that processor is only available through the CTO process or special bid.
  • Page 11: Memory Options

    Internal drives Models of the x3100 M5 with the compact tower form factor (and either a 300 W or a 350 W fixed power supply) support up to four 3.5-inch simple-swap SATA hard disk drives, as shown in the following figure.
  • Page 12 3TB 7.2K 6Gbps NL SATA 3.5" G2SS HDD Models of the x3100 M5 using the standard tower chassis (and with hot-swap 430 W power supplies) support either up to eight 2.5-inch hot-swap drives or four 3.5-inch hot-swap drives, as shown in the following figure.
  • Page 13 S3700 800GB SATA 2.5" MLC HS Enterprise SSD for System x 49Y6129 A3EW 200GB SAS 2.5" MLC HS Enterprise SSD 49Y6134 A3EY 400GB SAS 2.5" MLC HS Enterprise SSD 49Y6139 A3F0 800GB SAS 2.5" MLC HS Enterprise SSD System x3100 M5...
  • Page 14 3.5-inch NL SAS self-encyrping drives (SEDs) - 512e Advanced Format drives 00ML218 AS79 2TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED 00ML223 AS7A 4TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED 00ML228 AS7B 6TB 7.2K 6Gbps NL SAS 3.5" G2HS 512e SED System x3100 M5...
  • Page 15: Controllers For Internal Storage

    81Y4492 A1XL ServeRAID H1110 SAS/SATA Controller C5x, EEx 81Y4448 A1MZ ServeRAID M1115 SAS/SATA Controller F3x, EGx, EHx, EJx 81Y4481 A347 ServeRAID M5110 SAS/SATA Controller 46C8988 A3MW N2115 SAS/SATA HBA for System x 46M0907 5982 6Gb SAS HBA System x3100 M5...
  • Page 16 ServeRAID M5100 Series SSD Caching Enabler for System x * A cache option (81Y4484, 81Y4487, or 81Y4559) must be selected. ** For the standard tower chassis only (hot-swap power supplies). Not supported in the compact tower chassis. System x3100 M5...
  • Page 17: Internal Backup Units

    (81Y4508) or a flash upgrade is selected. Not supported in the compact tower chassis. For more information, see the list of Lenovo Press Product Guides in the RAID adapters category: http://lenovopress.com/systemx/raid Internal backup units The server supports the internal tape drive options that are listed in the following table.
  • Page 18: Optical Drives

    Slot 1, PCIe 3.0 x16 (x8 wired), full-height, half-length  Slot 2, PCIe 3.0 x8 (x8 wired), full-height, half-length  Slot 3, PCIe 2.0 x8 (x4 wired), full-height, half-length  Slot 4, PCIe 2.0 x4 (x1 wired), full-height, half-length  System x3100 M5...
  • Page 19: Network Adapters

    Network adapters The x3100 M5 offers two integrated Gigabit Ethernet ports. One port is shared with Integrated Management Module II (IMM2), implementing Network Controller-Sideband Interface (NC-SI). The integrated NICs have the following features: Broadcom BCM5717 chip  TCP/IP Offload Engine (TOE) support ...
  • Page 20: Storage Host Bus Adapters

    N2125 SAS/SATA HBA for System x 46M0907 5982 6 Gb SAS HBA Controller For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category: http://lenovopress.com/systemx/hba PCIe SSD adapters The server does not support High IOPS SSD adapters.
  • Page 21: Power Supplies

    System x3100 Operating Temperature Enhancement Kit for 4U Tower For standard tower systems (with hot-swap power supplies) 00Y8200 A49D System x3100 Thermal Solution Fan kit for 5U Tower 00FK940 A49C System x3100 Operating Temperature Enhancement Kit for 5U Tower System x3100 M5...
  • Page 22: Integrated Virtualization

    The following table lists the remote management option. Table 19. Remote management option Part Feature Description Maximum Models number code supported where used 90Y3901 A1ML Integrated Management Module Advanced Upgrade System x3100 M5...
  • Page 23: Supported Operating Systems

    10.0° to 43.0° C (50° to 109.4° F); maximum altitude: 2,133.6 m (7,000 ft)  Shipping -40° to 60° C (-40° to 140° F)  Relative humidity: 8 to 80%  Maximum altitude: 2,133.6 m (7,000 ft)  System x3100 M5...
  • Page 24 Ship configuration: 341 Btu/hr (100 watts)  Full configuration: 1726 Btu/hr (506 watts)  Noise level  Model with fixed power supply: 5.0 bels (idle), 5.0 bels (operating)  Model with hot-swap power supply: 5.0 bels (idle), 5.0 bels (operating)  System x3100 M5...
  • Page 25: Warranty Options

    Warranty options The x3100 M5 has a 1-year onsite warranty with 9x5/NBD terms. Lenovo offers warranty service upgrades through ServicePac offerings. The ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
  • Page 26: Regulatory Compliance

    Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU004/2011 (for safety)  IEC 60950-1 (CB Certificate and CB Test Report)  CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)  CISPR 22, Class A  TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)  System x3100 M5...
  • Page 27: External Disk Storage Expansion

    External disk storage expansion The x3100 M5 supports attachment to external storage expansion enclosures, such as the EXP2500 series, by using either the ServeRAID M5225 or ServeRAID M5120 RAID controllers. The server can also be attached to supported external storage systems by using a supported HBA.
  • Page 28 One of the available cache upgrades (81Y4484, 81Y4487, or 81Y4559) is required for the M5120 adapter operations, and it must be purchased together with the controller. For more information about the ServeRAID M5120, see the Lenovo Press Product Guide at http://lenovopress.com/tips0858 The ServeRAID M5120 SAS/SATA Controller supports connectivity to the external expansion enclosures that are listed in the following table.
  • Page 29 Lenovo ThinkServer SA120 support For details about supported drives and cables for the Lenovo ThinkServer SA120, see the Lenovo Press Product Guide: http://lenovopress.com/tips1234 EXP2512 and EXP2524 support The external SAS cables that are listed in the following table support connectivity between external expansion enclosures and the ServeRAID M5120 SAS/SATA Controller.
  • Page 30 600GB 10,000 rpm 6Gb SAS 2.5" HDD 00NC567 900GB 10,000 rpm 6Gb SAS 2.5" HDD 00NC569 1.2TB 10,000 rpm 6Gb SAS 2.5" HDD 2.5" SAS HS SSDs 00NC573 200GB 6Gb SAS 2.5" SSD 00NC575 400GB 6Gb SAS 2.5" SSD System x3100 M5...
  • Page 31: External Disk Storage Systems

    IBM Storwize V7000 2.5-inch Storage Controller Unit 6195LEF IBM Storwize V7000 3.5-inch Storage Expansion Unit 6195SEF IBM Storwize V7000 2.5-inch Storage Expansion Unit For more information, see the list of Lenovo Press Product Guides in the System Storage category: http://lenovopress.com/systemx/externalstorage System x3100 M5...
  • Page 32: External Backup Units

    See the IBM System Storage Interoperation Center (SSIC) for further information. For more information, see the list of Lenovo Press Product Guides in the Backup units category: http://lenovopress.com/systemx/tape System x3100 M5...
  • Page 33: Top-Of-Rack Ethernet Switches

    Top-of-rack Ethernet switches The server supports the top-of-rack Ethernet switches from Lenovo that are listed in the following table. Table 28. Top-of-rack switches Part number Description 1 Gb top-of-rack switches 7309BAX RackSwitch G7028 (24 ports) 7309CAX RackSwitch G7028 (48 ports)
  • Page 34: Uninterruptible Power Supply Units

    6000VA LCD 4U Rack UPS (200 V/208 V) 53956KX 6000VA LCD 4U Rack UPS (230 V) 53959KX 11000VA LCD 5U Rack UPS (200V/208V/230V) For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://lenovopress.com/systemx/power System x3100 M5...
  • Page 35: Power Distribution Units

    DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd connector 39Y8935 DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd connector 39Y8938 30amp/125V Front-end PDU with NEMA L5-30P connector 39Y8939 30amp/250V Front-end PDU with NEMA L6-30P connector 39Y8940 60amp/250V Front-end PDU with IEC 309 60A 2P+N+Gnd connector System x3100 M5...
  • Page 36 0U 24 C13 32A PDU 46M4140 0U 12 C19/12 C13 60A 3 Phase PDU 46M4143 0U 12 C19/12 C13 32A 3 Phase PDU For more information, see the list of Lenovo Press Product Guides in the Power infrastructure category: http://lenovopress.com/systemx/power System x3100 M5...
  • Page 37: Racks Cabinets

    Tower to 5U Rack Conversion Kit for System x3100 M5 (for systems with hot-swap power supplies) 69Y5182 Tower to 4U Rack Conversion Kit for System x3100 M5 (for systems with fixed power supplies) 93072PX 25U Static S2 Standard Rack 93072RX...
  • Page 38: Rack Options

    Long KVM Conversion Option (4 Pack Long KCO) 46M5383 5341 Virtual Media Conversion Option Gen2 (VCO2) 46M5382 5340 Serial Conversion Option (SCO) For more information, see the list of Lenovo Press Product Guides in the Rack cabinets and options category: http://lenovopress.com/systemx/rack System x3100 M5...
  • Page 39: Lenovo Financial Services

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovo.com/services_warranty/us/en/financial_services.html...
  • Page 40: Related Publications And Links

    System x3100 M5 product page  http://www.ibm.com/systems/x/hardware/tower/x3100m5 System x3100 M5 Installation and Service Guide  http://ibm.com/support System x Information Center  http://publib.boulder.ibm.com/infocenter/systemx/documentation ServerProven hardware compatibility page for the x3100 M5  http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/5457.html Configuration and Option Guide  http://www.ibm.com/systems/xbc/cog/ xREF: System x Reference  http://lenovopress.com/xref System x Support Portal ...
  • Page 41 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 42 Trademarks Lenovo, For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published.

Table of Contents