Wiring the 491

Electrical power
requirements
Connecting the 491
to ship's power
Connecting the 491
to the 961/962
491 INSTALLATION MANUAL Revision A
CAUTION!
The majority of installation problems are caused by shortcuts taken with
system cables. When installing the 491, be sure that you:
assemble connectors carefully
don't make sharp bends in the cables
leave service and drip loops, so that moisture won't run down the
cables and into the 491 or the navigator
tie-wrap all cables to keep them secure
if cables are shortened, lengthened (not recommended), or re-termi-
nated, seal all wiring splices
prevent interference from the transducer cable
The 491 is a negative-ground system that is reverse-polarity and over-
voltage protected. The unit requires 8 to 36 VDC power at 8 Watts.
The connection between ship's power and the 491 requires the 10-foot
(3-meter) power cable supplied with the 491.
The wires in the power cable must be connected as follows (black and
white can be connected together at the power source):
Red → Positive (+) (fused lead)
Black → Negative (–)
Green → Ground (earth)
NOTE:
The 491 should be grounded to the vessel to eliminate interfer-
ence. Secure the green wire to the vessel's nearest grounding
point. Without an earth grounding, performance may be degraded.
The connection between the 961/962 and the 491 uses the 10-foot
(3-meter) data cable supplied with the 491. The cable connects to the P1
slot on the back of the navigator.
The cable is shipped with a round 6-pin connector that attaches to other
Northstar navigators. To install the 491 with a 961 or 962, you must cut
off and discard the 6-pin connector, and wire the cable as shown below.
Be sure you don't cut off the 8-pin connector that plugs into the 491!
Figure 8 below illustrates the wiring at the 961/962 end of the cable.
Table 4 describes the pin's functions.
SECTION THREE — Installing the 491
Make sure that fuse or circuit-breaker protection is
provided at the power source.
PAGE 15