NorthStar EXPLORER D210 Installation And Operation Manual

Northstar navigation sonar - depth sounder user manual

Advertisement

Explorer D210
Installation and Operation Manual
www.northstarnav.com

Advertisement

Table of Contents
loading

Summary of Contents for NorthStar EXPLORER D210

  • Page 1 Explorer D210 Installation and Operation Manual www.northstarnav.com...
  • Page 2 Technologies Inc. and its subsidiaries and affiliates reserve the right to make changes to specifications without notice. Copyright © 2006 Brunswick New Technologies Inc. Northstar™ is a registered trademark of Brunswick New Technologies Inc Northstar Explorer D210 Installation and Operation Manual...
  • Page 3: Table Of Contents

    Instrument Installation ............. . 8 6 Wiring ... 9 Appendix A - Specifications ... 10 Appendix B - Troubleshooting ... 11 Appendix C - How to contact us ... 12 Northstar Explorer D210 Installation and Operation Manual...
  • Page 4: Operation

    1. Press show: 2. After two seconds the display will indicate the current Deep Alarm depth setting. Northstar Explorer D210 Installation and Operation Manual for three seconds. The display will to change the value. If either simultaneously. Alternatively, if no Press simultaneously to exit for three seconds.
  • Page 5: Instrument Setup

    5 seconds normal depth display will resume. The display will now indicate the current water depth. Northstar Explorer D210 Installation and Operation Manual Press simultaneously to exit for 5 seconds. to change the value. If either simultaneously.
  • Page 6: Transducer Setting

    Transducer Setting A Transducer Setting is provided to allow the Explorer D210 to be used with different transducer types. The default setting (= 0.0) is used for most transducers. Some transducers ‘ring’ after the sonar transmit pulse (just like hitting a bell). This ringing can be interpreted as an echo from a shallow bottom.
  • Page 7: Master/Slave Selection

    Note: If the data link is inadvertently broken then the display will alternate between -- and -SL. Linked or Separate Selection By default a dual station pair of Explorer D210 instruments automatically keep the following settings the same in both instruments:...
  • Page 8: Maintenance

    Following the operation and installation guidelines in this manual should ensure optimum performance of the instrument. In the unlikely event that the instrument shall fail to perform or shall need servicing, contact the dealer whom you purchased your Explorer D210 from. 5 Installation...
  • Page 9: Wiring

    If unused then tape to avoid shorting. • Brown Data input/output Your Explorer D210 can be used as a repeater for another DPT or DBT NEMA depth sounder. If unused then tape to avoid shorting. RCA Jack Connector If unsure about wiring contact your nearest Northstar dealer.
  • Page 10: Appendix A - Specifications

    RF Interference <6 dB quieting on any marine radio channel (with 3 dB gain antenna) within one meter of the instrument. Complies with CE EMC standards EN50081-1 and EN50082-1. Northstar Explorer D210 Installation and Operation Manual Alarm Off/ Change Value Down...
  • Page 11: Appendix B - Troubleshooting

    2. Check the transducer cable for cuts and sharp bends. 3. Check that the transducer connection behind the Explorer D210 is firm and free of corrosion. Erratic readings while moored: 1. Check transducer for growth or multiple coats of paint.
  • Page 12: Appendix C - How To Contact Us

    AMERICAS 30 Sudbury Road, Acton, MA 01720, USA Ph: +1 978.897.6600 Ph: +1 800.628.4487 Fax: +1 978.897.7241 sales@bntmarine.com AUSTRALIA PO Box 479, Gladesville, NSW 2111, AUSTRALIA Ph: +61 2 9879 9060 Fax: +61 2 9879 9009 northstaraus@northstarnav.com www.northstarnav.com EUROPE Unit 2, Ocean Quay, Belvidere Rd, Southampton, SO14 5QY, ENGLAND Ph: +44 2380 339922...

Table of Contents