Instrument Installation ............. . 8 6 Wiring ... 9 Appendix A - Specifications ... 10 Appendix B - Troubleshooting ... 11 Appendix C - How to contact us ... 12 Northstar Explorer D210 Installation and Operation Manual...
1. Press show: 2. After two seconds the display will indicate the current Deep Alarm depth setting. Northstar Explorer D210 Installation and Operation Manual for three seconds. The display will to change the value. If either simultaneously. Alternatively, if no Press simultaneously to exit for three seconds.
5 seconds normal depth display will resume. The display will now indicate the current water depth. Northstar Explorer D210 Installation and Operation Manual Press simultaneously to exit for 5 seconds. to change the value. If either simultaneously.
Transducer Setting A Transducer Setting is provided to allow the Explorer D210 to be used with different transducer types. The default setting (= 0.0) is used for most transducers. Some transducers ‘ring’ after the sonar transmit pulse (just like hitting a bell). This ringing can be interpreted as an echo from a shallow bottom.
Note: If the data link is inadvertently broken then the display will alternate between -- and -SL. Linked or Separate Selection By default a dual station pair of Explorer D210 instruments automatically keep the following settings the same in both instruments:...
Following the operation and installation guidelines in this manual should ensure optimum performance of the instrument. In the unlikely event that the instrument shall fail to perform or shall need servicing, contact the dealer whom you purchased your Explorer D210 from. 5 Installation...
If unused then tape to avoid shorting. • Brown Data input/output Your Explorer D210 can be used as a repeater for another DPT or DBT NEMA depth sounder. If unused then tape to avoid shorting. RCA Jack Connector If unsure about wiring contact your nearest Northstar dealer.
RF Interference <6 dB quieting on any marine radio channel (with 3 dB gain antenna) within one meter of the instrument. Complies with CE EMC standards EN50081-1 and EN50082-1. Northstar Explorer D210 Installation and Operation Manual Alarm Off/ Change Value Down...
2. Check the transducer cable for cuts and sharp bends. 3. Check that the transducer connection behind the Explorer D210 is firm and free of corrosion. Erratic readings while moored: 1. Check transducer for growth or multiple coats of paint.
Need help?
Do you have a question about the EXPLORER D210 and is the answer not in the manual?
Questions and answers