Drivers - HP HPE ProLiant ML30 Gen9 User Manual

Hide thumbs Also See for HPE ProLiant ML30 Gen9:
Table of Contents

Advertisement

Copy the binary file to a USB media or iLO virtual media.
2.
Attach the media to the server.
3.
Boot to Embedded Shell.
4.
To obtain the assigned file system volume for the USB key, enter Map –r . For more information
5.
about accessing a file system from the shell, see the UEFI Shell User Guide for ProLiant Gen9
Servers on the Hewlett Packard Enterprise website (http://www.hpe.com/info/ProLiantUEFI/docs).
Change to the file system that contains the System ROM Flash Binary component for your server.
6.
Enter one of the fsx file systems available, such as fs0 or fs1, and press Enter.
Use the cd command to change from the current directory to the directory that contains the binary
7.
file.
Enter fwupdate –d BIOS -f <filename> to flash the system ROM.
8.
For help on the FWUPDATE command, enter the command:
help fwupdate -b
Reboot the server. A reboot is required after the firmware update for the updates to take effect and
9.
for hardware stability to be maintained.
For more information about the commands used in this procedure, see the UEFI Shell User Guide for
ProLiant Gen9 Servers on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/ProLiantUEFI/docs).
Firmware Update application in System Utilities
For systems configured in either boot mode, update the firmware:
Access the System ROM Flash Binary component for your server from the Hewlett Packard
1.
Enterprise Support Center website (http://www.hpe.com/support/hpesc). When searching for the
component, always select OS Independent to find the component.
Copy the binary file to a USB media or iLO virtual media.
2.
Attach the media to the server.
3.
During POST, press F9 to enter System Utilities.
4.
Select Embedded Applications → Firmware Update → System ROM → Select Firmware File.
5.
Select the device containing the flash file.
6.
Select the flash file. This step may take a few moments to complete.
7.
Select Start firmware update and allow the process to complete.
8.
Reboot the server. A reboot is required after the firmware update for the updates to take effect and
9.
for hardware stability to be maintained.
Online Flash components
This component provides updated system firmware that can be installed directly on supported Operating
Systems. Additionally, when used in conjunction with the HP SUM
82), this Smart Component allows the user to update firmware on remote servers from a central location.
This remote deployment capability eliminates the need for the user to be physically present at the server
to perform a firmware update.

Drivers

IMPORTANT: Always perform a backup before installing or updating device drivers.
The server includes new hardware that may not have driver support on all OS installation media.
("HP Smart Update
Manager" on page
Software and configuration utilities 88

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPE ProLiant ML30 Gen9 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF