  • Page 2: Data Field Programming Procedures

    TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. A. POWER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method must be used to reenter program mode).
  • Page 3: Installer Code

    352*5$00,1*)250 Programmable values apply to all controls, except field *189, which applies to the VISTA-20PS only. Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Entries shown in dashed boxes indicate partition entries for VISTA-20P only (not applicable for VISTA-15P). Field Function Data Entries...
  • Page 4: Split/Dual Reporting

    A 0 ( not #+10) in the second box will eliminate the expanded message for that report. A 0 ( not #+10) in both boxes will disable the report. For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).
  • Page 5: Option Selection

    ✱ 65 OPEN REPORT CODE [0,0,0] See box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE [00] See box on previous page.
  • Page 6: Download Phone No

    ✱ 92 Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min PHONE LINE MONITOR ENABLE [0,0] (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+15 = 15 min) UL: see Inst.
  • Page 7: Symphony (Aui) Enable

    MISCELLANEOUS SYSTEM FIELDS (*174-*181) ✱ 174 CLEAN ME REPORTING OPTIONS 0 = disable; 1 = Clean Me signal reports; Note: If Clean Me is enabled, you must enter “3” in (for ESL smoke detectors) field ✱56 programming for zone 1 response time. ✱...
  • Page 8: Configurable Zone Types Worksheets

    Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
  • Page 9 *56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34) [default shown in brackets] Zone Zn Type Part. Report Hardwire Rsp. Time Location Type [09] [EOL] [01] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] Zone...
  • Page 10 *57 FUNCTION KEY PROGRAMMING Option Function Comments Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Macro Key 2 Macro Key 3 Macro Key 4 Emergency Keys: zone 95 zone 99 zone 96 paging Personal Emergency...
  • Page 11: Output Definitions

    ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. 2.
  • Page 12: Zone Type Definitions

    Zone Type Definitions Type 00 Use this zone type if the zone is not used. Zone Not Used Type 01 • Assign to zones that are used for primary entry and exit. Entry/Exit Burglary #1 • Provides entry delay if the control is armed in the Away or Stay modes. •...
  • Page 13 Type 21 • Arms the system in Away mode when the zone is activated. Arm-Away • Pushbutton units send the user number to the central station when arming or disarming. • User code for button must be assigned. Type 22 •...
  • Page 14: Alpha Vocabulary List (For Entering Zone Descriptors)

    ALPHA VOCABULARY LIST (For Entering Zone Descriptors) (Word Space) – L – – R – – V – • 057 DOOR ∗ • 106 LAUNDRY ∗ RADIO VALVE – A – • 059 DOWN VAULT • 107 LEFT • 156 REAR •...
  • Page 15: 5800 Series Transmitter Input Loop Identification

    5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). WIRELESS INPUT TYPES "RF"...