Sanyo abc-vw24 Service Manual page 9

Hide thumbs Also See for abc-vw24:
Table of Contents

Advertisement

Operation of the Sterilized and Electrolyzed Mist
<Lamp Display and Status Chart>
Electrolyzing
Add Water
* When the lamp has been lit or is flashing, please wait 15 seconds before resetting the tank.
Electrolyzing off
Off
Tank setting malfunction (tank-attached detection switch off)
Electrolyzing on <Normal>
On
When electrolyzing is switched off, the electrode is energized
for a 4-minute period once every 8 hours or so for the
purpose of purifying the water in the tank.
(This is not a malfunction.)
*When the equipment is used as normal with electrolyzing
on, the processing of the water in the tank makes it sterile,
Flashing
but when electrolyzing is switched off, the water purification
process (energizing of the electrode) is run about once
every 8 hours in order to avoid neglecting the water in the
tank for long periods of time.
Off
<Normal>
There is no water left in the tank so please fill the tank with water.
On
Operational error in the electrolyzing unit (open)
The tank setting status has continued unchanged for 21 days.
Please change the water.
Operational error in the electrolyzing unit (short circuit)
*When the same water is used for a long period of time,
Flashing
concentration becomes very high so please change the water
in the tank 21 days after the tank has been filled and attached to
the main unit. (When the unit is used normally, the water will
run out before 21 days and the light will be lit.)
- 9-
ABC-VW24