NEC SL1100 Programming Manual page 318

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Item
No.
09
DISA Internal
Paging Time
10
DISA External
Paging Time
11
VRS/DISA An-
swer Delay Time
Program
25
13
VRS/DISA Busy
Tone Interval
14
Delayed VRS An-
swer Time
Conditions
None
Feature Cross Reference
• Direct Inward System Access (DISA)
2-298
Item
Input Data
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
Description
This is the maximum length of an In-
ternal Page placed by a DISA caller.
If the Page continues longer than
this time, the system terminates the
DISA call.
This is the maximum length of an
External Page placed by a DISA
caller. If the Page continues longer
than this time, the system termi-
nates the DISA call.
Sets up the time the system waits
after receiving an incoming VRS/
DISA call before the system auto-
matically answers the call.
If a DISA caller dials a busy exten-
sion (and Program 25-04 = 0), the
system plays busy tone for this time
before disconnecting.
Assign the delay time from switching
from a normal incoming status to
DID mode. If this time is set to 0, the
call switches to DID mode immedi-
ately.
Program 25 : VRS/DISA Setup
ISSUE 6.0
Default
Related
Program
30 seconds
20-31-21
30 seconds
20-31-22
0 second
5 seconds
10 seconds

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents