Bag containing: 2 screws, cable blank and cable clamp. Instruction leaflet. The TGBT4 is a boost timer giving a range of boost times from 1/4hr to 2hrs covering the majority of requirements for heating, ventilation and lighting (a light switch may be replaced by this unit if a neutral is available).
Fig. 2 TGBT4 Rear Connections The unit is designed to replace an existing single gang connection unit, socket outlet or fixed appliance outlet. The unit is capable of forming part of a ring main (the terminals can accept 2 x 2.5mm sq. cables) or terminating a spur off the ring main.
3. Operation The required boost time is selected by pressing the button marked Boost repeatedly. The LED’s adjacent to the time markers (above the Boost button) will light up in the sequence:- First push gives 1/4hr boost (LED opposite 1/4 is on) Second push gives 1/2hr boost (LED’s opposite 1/4 and 1/2 are on) Third push gives 1hr boost (LED’s opposite 1/4, 1/2 and 1 are on)
4. Specifications This product complies with: LVD Directive 72/23/EEC. EMC Directive 89/336/EEC. and relevant clauses of the following standards: BS EN 60730-7-2:1992; Particular requirements. Timers and time switches. Permissable loads: 13A resistive. 5A inductive. 1000W filament lamps. 500W fluorescent lighting. 100W low energy lamps.
3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge.
Need help?
Do you have a question about the TGBT4 and is the answer not in the manual?
Questions and answers