Models:
DV330AEW DV330AGW
DV330AEB DV330AGB
NOTICE: All Dryers Parts
Change 6/2010: Motor Pulley,
page 5; Blower Housing, page 4
Display
dO
dE
FE
dF
hE or HE
bE
od
SUPPORT INFORMATION
Training — Plus One
http://my.plus1solutions.net/clientPortals/samsung/
Help — GSPN
http://service.samsungportal.com/
Samsung Product Support TV
http://support-us.samsung.com/spstv/howto.jsp
Customer information videos and chat programs
Programs for Fridges, Laundry, Ranges & D/W
IMPORTANT SAFETY NOTICE – "For Technicians Only" This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
Samsung 'Dryer' Diagnostic Code Quick Guide
Description
Dryer Thermistor Short
Sensed
Dryer Thermistor Open
Sensed
Door Open
Power source frequency
Error
Door Circuit Failure
Heater Error
Button Error
Over Dry
EEprom Fail
Fast Track Troubleshooting
Publication # tsDV330 Revision Date 06/27/2011
Trigger
The Thermistor resistance is
very low.
The Thermistor resistance is
very high.
Running the dryer with door
open
Invalid power source Frequency Check for: Non Utility power supply
Invalid state for more than 256
milliseconds
Invalid heating Temp in running
the dryer
PCB key closed for 75 sec.
Invaled Dry Time Excessive Dry
Time
Invalid state of Eeprom
communication
Electrical Dryers 240 VAC, 60 Hz, 30 Amps, 3
-wire or 4-wire installations
Gas Dryers 120 VAC, 60 Hz, 15 Amps, 3-wire
installations
Location consideration In the USA
All Dryers Must be vented to the outside.
Only rigid or flexible metal duct should be
used for venting.
Action Taken
Check for: Clogged lint screen,
Restricted vent system, Thermistor
resistance.
Check for: Clogged lint screen,
Restricted vent system, Thermistor
resistance.
Check for: Loose or open wire
terminals in Door Sense circuit.
Check for: Loose or open wire
terminals in Door Sense circuit.
Check for: Restricted vent system,
Thermistor resistance.
Check Display PCB for stuck button
Inspect seensor bars
Replace Main PCB
:
Need help?
Do you have a question about the DV330AEW and is the answer not in the manual?
Questions and answers