Miele KM 6304 Operating And Installation Instructions page 50

Ceramic cooktops with induction
Table of Contents

Advertisement

Problem solving guide
Problem
Power level 9 is
automatically reduced
if you select power
level 9 on two linked
cooking zones or
extended zones at the
same time.
The cooktop switches
off while it is in use and
an F flashes in the timer
display.
The food in the pan
hardly heats up or does
not heat up at all when
the Auto heat-up
function is switched
on.
The cooling fan
continues to run after
the appliance has been
switched off.
50
Possible cause
Operating both zones
at power level 9 would
exceed the permitted
maximum power level
for the two zones.
One or more of the
sensors have been
covered, e.g. by finger
contact, food boiling
over or by an object
such as an oven glove.
There is too much food
in the pan.
The pan is not
conducting heat
properly.
The fan will continue
running until the
appliance has cooled
down. It will then
switch itself off
automatically.
Remedy
Clean the control panel or
remove the obstruction (see
"Safety switch-off").
Start cooking at the highest
power level and then turn
down to a lower one
manually later on.