The washer must only be installed by a
Miele authorized service technician.
Before installation or service disconnect
the power supply to the work area.
The minimum dimensions and distance
required from the wall, as shown in the
installation diagram, must be observed to
allow service to be performed and the
data plate to be viewed.

Installation site

A concrete or reinforced floor is the most
suitable surface for the washer. These types
of floors are less prone to vibration during
the spin cycle.
The washer must be leveled for proper
operation. The machine does not need to be
installed on a base, however, any
unevenness in the floor must be
compensated for.
Do not install or store this machine in a
room where temperatures below freezing
may occur or where the machine may be
exposed to the weather.
Do not install the washer on carpeting.
Carpeting will block the washers air vents.

Installation Instructions

Removing the shipping struts

^ The red-marked fixing angles "A" on the
diagram, 2 on each side panel are fixed
with 3 M 10 (SW 17) hex screws. Remove
these.
The red-marked shipping struts "B" on the
diagram, 2 at the front and 2 at the rear are
each fixed with 3 M 10 (SW 17) hex screws.
^ To remove them detach the front service
panel and the rear panel. Unscrew the 3
M6 hex screws (SW 8) at the bottom edge
of the front service panel, and take it off.
Unscrew 8 hex screws in the rear panel
and remove.
The cover for the bottom front and the rear
panels are secured to the side panels, and
should be fitted when the machine has been
installed. Use the supplied screws.
The shipping struts should be stored in a
safe place for future use. They must be
refitted if the machine is moved.