Panasonic CS-KS30NKU Technical & Service Manual page 28

Table of Contents

Advertisement

Indoor Unit
CS-KS36NKU
Outdoor Unit CU-KS36NKUA
(1) Voltage:230V
Cooling
Performance at
Rating conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
(2) Voltage:208V
Cooling
Performance at
Rating conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Running amp.
A
Power input
W
80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB
95 °F (35 °C) DB
Running amp.
A
Power input
W
80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB
95 °F (35 °C) DB
Indoor
UnitOutdoor Unit
Fan Motor
Fan Motor + Compressor
230V Single-phase 60Hz
0.4
39
Indoor
UnitOutdoor Unit
Fan Motor
Fan Motor + Compressor
208V Single-phase 60Hz
0.4
39
28
Complete Unit
19.6
3,961
4,000
Complete Unit
21.5
3,961
4,000
<
>
230V
20.0
<
>
208V
21.9