S-Register 38—Disconnect Buffer Delay
Stored in Nonvolatile Memory?:
Status-Only?:
Default:
Range:
S-Register 38 determines how long the modem processes buffered data when a
disconnect is initiated. For S-Register 38 to affect the Delay option (AT
Delay (EC OPT'S menu) must be set to "Buf or S38" or "Buf & S38."
S-Register 45—Access Security Tone Duration
Stored in Nonvolatile Memory?:
Status-Only?:
Default:
Range:
This S-Register specifies the prompt tone duration when the ACCESS SECURITY
option Tone=Prompt Only or Prompt/Ack (AT
the time that the prompt tone is generated by the answer modem, to the time that the
answer modem detects the first digit of the calling modem's password.
S-Register 46—Access Security Lead Digit Delay Timeout
Stored in Nonvolatile Memory?:
Status-Only?:
Default:
Range:
This S-Register specifies the lead digit delay timeout when ACCESS SECURITY
Tone (AT
S-Register 96—Signalling System #5
Stored in Nonvolatile Memory?:
Status-Only?:
Default:
Range:
This S-Register specifies whether Signalling System #5 is enabled.
5-16 Using the AT Automatic Calling Interface
Yes
No
5
0 to 255 (seconds)
Yes
No
5
0 to 10 (seconds)
Yes
No
12
0 to 255 (seconds)
*
ZP) is enabled.
Yes
No
0
0 - 1
*
*