HELMUTH JOSEF RONACHER
February 12, 2025

The Evo 5 does not respond to remote controls

James Keulder
March 8, 2025

Is it possible to draw a report from the D10 Smart motor of all remotes that have been configured? I find doing it on the phone cumbersome as you have to record it by hand. The log report is brilliant but does not give me what I want.

1 comments:
Mr. Anderson
March 8, 2025

Yes, the Centurion D10 Smart motor can record the memory location of each remote control and map it to the owner's name if recorded. This allows tracking of all configured remotes, enabling selective deletion or modification of remote functions.

This answer is automatically generated

Summary of Contents for Centurion D10

  • Page 1 D5-Evo, D10 and D10 Turbo User Guide LIGHT- INDUSTRIAL SLIDING GATE OPERATOR page 1 www.CentSys.com...
  • Page 2 Americas, Australia and the Pacific Centurion Systems (Pty) Ltd reserves the right to make changes to the products described in this manual without notice and without obligation of Centurion Systems (Pty) Ltd to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd makes no representations or warranties with respect to this manual.
  • Page 3: Table Of Contents

    D10 overview page 10 1. Product Identification page 11 1.1. D5-Evo DOMESTIC parts identification page 11 1.2. D10 Turbo and D10 parts identification page 12 2. D5-Evo DOMESTIC manual Override page 13 2.1. Disengage the gearbox/drive page 13 2.2. Re-engage the gearbox/drive page 13 3.
  • Page 4 5. Additional features page 35 5.1. Battery saver page 35 5.2. Solar power supply page 35 5.2.1 D5-Evo DOMESTIC page 35 5.2.2 D10 Turbo and D10 page 36 5.3 Lightning protection page 36 6. Basic Maintenance page 37 7. Diagnostics page 39 8.
  • Page 5 Icons Used in this Manual This icon indicates tips and other information that could be useful during the installation. This icon denotes variations and other aspects that should be considered during installation. This icon indicates warning, caution or attention! Please take special note of critical aspects that MUST be adhered to in order to prevent injury.
  • Page 6: Safety First Important Safety Instructions

    Although years of thought have been put into every CENTURION product – and your safety is our top priority – accidents do happen. So, please make sure that you fully understand the following safety requirements before using your automated gate.
  • Page 7 CENTURION operator should last you a very long time. • Ensure that any technician that works on your operator has been trained by Centurion Systems (Pty) Ltd. • This product was designed and built strictly for the use indicated in the documentation provided with the product;...
  • Page 8: Introduction

    Even basic maintenance is covered but, in the unlikely event that your CENTURION product malfunctions, rather leave it to the professionals and contact your installer or nearest Centurion Systems (Pty) Ltd Branch (contact details listed on the back page) for prompt assistance.
  • Page 9: D5-Evo Domestic Overview

    The gearbox of the D10 Turbo utilises a “true” or “full involute” gear instead of a helical gear, which means that there is a larger contact area with the worm shaft, ensuring much greater load bearing capabilities.
  • Page 10: D10 Overview

    220V mains supply at the gate. As with the D5 Evo, the D10 controller with LCD interface is a cinch to set up and it offers an equally impressive list of useful features including Centurion’s ChronoGuard timer technology.
  • Page 11: Product Identification

    1. Product Identification 1.1. D5-Evo DOMESTIC parts identification FIGURE 1. D5-EVO DOMESTIC GATE MOTOR 1. D5-Evo DOMESTIC controller 7. Foundation plate 2. Courtesy light fuse (3A F/B) 8. Motor fuse (30A ATO) 3. Gate mounted origin Marker 9. 1 x 12V 7.2Ah battery 4.
  • Page 12: D10 Turbo And D10 Parts Identification

    1.2. D10/ D10 Turbo parts identification FIGURE 2. D10/ D10 TURBO GATE MOTOR D10/ D10 Turbo controller Foundation plate Courtesy light fuse (3A F/B) Motor fuse (30A ATO) 2 x 12V 7.2Ah battery 10. D10/ D10 Turbo charger Gate mounted origin Marker 11.
  • Page 13: D5-Evo Domestic Manual Override

    2. D5-Evo DOMESTIC Manual Override 2.1. Disengaging the gearbox/drive Carefully flip to the side the camlock cover and insert the key and rotate it 90° clockwise. While holding onto the key, pull open the access door to expose the manual override thumbwheel. This will allow for the removal of the cover, as well as for the rotation of the release thumbwheel.
  • Page 14: D10 Turbo D10 Manual Override

    3. D10/ D10 Turbo Manual Override 3.1. Disengaging the gearbox/drive Flip down the lock cover and Insert the camlock key and rotate it 90° clockwise. FIGURE 5 Pull down the manual release handle to override the gearbox and allow it to be moved manually.
  • Page 15 Insert the split pin (supplied with the mounting hardware kit), through the hole in the gearbox as indicated Split pin FIGURE 7 Make sure the split pin goes all the way through as shown Split pin FIGURE 8 Raise the handle and lock Remove the key and fold back the lock cover FIGURE 9...
  • Page 16: Features And Functions

    4. Features and Functions Introduction The D5-Evo DOMESTIC and D10 sliding gate operators’ advanced functions are controlled by intelligent micro-controller based electronic controllers. An intuitive LCD (Liquid Crystal Display) controller with a user-friendly menu allows for quick and easy set-up and the ability to change functions at the touch of a button and displays useful diagnostics.
  • Page 17: Modes Of Operation

    4.1.2. Modes of Operation To operate the gate to open fully, the D5-Evo DOMESTIC, D10 and D10 Turbo have a number of operating modes to choose from depending on the application. Only one mode can be selected at any given time, unless indicated otherwise.
  • Page 18: Plc Mode

    Mode 4.1.3. Automatic closing (Autoclose Mode) The D5-Evo DOMESTIC and the D10 sliding gate operators have the facility to automatically close the gate after it has opened. When enabling this feature, the time that the gate stays open is by default fifteen seconds (this time is adjustable As described in the previous section Autoclose is selectable with Standard and Reversing Modes and by default the function is off.
  • Page 19: Autoclose Override

    Your gate will stay open until you use the remote control or intercom gate release to close the gate. The D5-Evo DOMESTIC, the D10 and the D10 Turbo will then revert to normal Autoclose operation The Autoclose function cannot be overridden in Condominium Mode.
  • Page 20: Autoclose Advanced Option

    4.1.3.2. Autoclose Advanced Options You can also independently set Autoclose to function when the gate is partly open, fully open or partly closed. For example, disable Autoclose when the gate is partly closed to allow construction workers, gardeners, etc access to your property (although this comes with security risks).
  • Page 21 If the Courtesy Light (Page 20) is connected to the control card, it will flash indicating that the gate will open a default distance of approximately one metre (adjustable). The gate will close after a default time of five seconds (adjustable). The gate can be kept open by keeping a trigger on the input (keeping your key in the keyswitch, for example) –...
  • Page 22: Free-Exit Opening

    (or any object) moves through it, so this option is typically less secure. Please contact Centurion Systems (Pty) Ltd for more information on whether a ground loop or infrared beam is better suited to your needs. page 22...
  • Page 23: Pirac Mode (Beam Autoclose) - Optional

    4.1.6. PIRAC Mode (Beam Autoclose Mode) - Optional This mode can only be used if a Closing Safety Beam is fitted. This mode can be used in Gate opening conjunction with any of the operating modes - Standard, Condominium and Reversing Mode. With PIRAC Mode enabled, your gate will close as soon as you have driven through and passed the Closing...
  • Page 24: Pirac Override

    PIRAC Mode overridden. Your gate will stay open until you use the remote control or intercom gate release to close the gate. The D5-Evo DOMESTIC, D10 and the D10 Turbo will then revert to normal PIRAC operation.
  • Page 25: Emergency Stop

    4.1.9. Operator Run Profiles The D5-Evo DOMESTIC, D10 and the D10 Turbo can be customised to your exact requirements using your LCD controller. The open and closing speeds can be independently set.
  • Page 26: Anti-Crushing Sensitivity

    4.1.10. Anti-crushing Sensitivity The D5-Evo DOMESTIC, D10 and the D10 Turbo incorporate a sensitive electronic anticrushing technology that activates if a person or vehicle obstructs your gate. The operator will respond differently to obstructions depending on the Operating Standard (e.g. CE, UL325) you select.
  • Page 27: Safety Beams (Optional, But Recommended Feature)

    (large metal objects) and provide no protection to people or other objects in the path of the gate. Please contact Centurion Systems (Pty) Ltd for more information on suitable protection devices. 4.1.11.2. Opening Safety Beams...
  • Page 28: Intruder Detection Alarm (A World First)

    • Auxiliary IO (which can be used to connect to a third party alarm and security company, or a CENTURION G-Switch device to alert you of the alarm via SMS) It is typical to select only one of the alarm features.
  • Page 29: External Gate Status Indication Led

    4.1.13. External Gate Status Indication A LED (Light Emitting Diode) mounted on your intercom allows you to view the position of your gate and the condition of the battery and power supply from the safety of your home. The different signals of the LED are described below: FIGURE 28 LED Signal...
  • Page 30: Courtesy (Pillar) Light Timer (Optional Feature)

    The Courtesy (Pillar) Lights can be switched on from inside your home or office by connecting a pushbutton to the D5-Evo DOMESTIC, D10 or D10 Turbo controller. For your safety this pushbutton switches only low-voltage signals. Press and release the button for the lights to switch on for the defined period then switch off automatically.
  • Page 31: Courtesy (Pillar) Light Act As Warning Light

    FIGURE 31 You can artificially increase the number of buttons of a CENTURION multi-button remote control by using a two button combination. One of the buttons is used as a shift button to allow the other buttons to be used again in combination with this button. Press and hold the shift button and then press one of the other buttons to create a new button.
  • Page 32 Alternatively, the functionality of certain buttons can be changed to trigger different functions. At any stage remote controls can be selectively added, deleted or edited within the system. Contact your gate automation specialist or Centurion Systems (Pty) Ltd for assistance. page 32 www.CentSys.com...
  • Page 33: Chronoguard Timer (A World First)

    ChronoGuard™ (a world first) is a powerful multichannel timer feature which has been added to the D5-Evo DOMESTIC, D10 and D10 Turbo controllers. A Real Time Clock and Calendar (RTC) lets you set the following features to operate automatically or be prevented from operating (time-barred) during any Time-period you choose: •...
  • Page 34: Battery Low Protection

    The gate will complete its current cycle, close and then shut down until the battery voltage has recovered. If you see the Battery Low signal, check that the power circuit feeding the gate motor is switched on otherwise contact your gate automation specialist or Centurion Systems (Pty) Ltd for assistance. page 34...
  • Page 35: Additional Features

    The charger supplied with the standard D5-Evo DOMESTIC system must also be replaced with a high efficiency solar regulator. These are typical values for Southern Africa. Contact Centurion Systems (Pty) Ltd or your gate automation specialist for details on what solar panel to select in your area.
  • Page 36: Lightning Protection

    5.2.2. D10 and D10 Turbo It is possible to adapt in the D10 as well as D10 Turbo for solar charging; however, typically 2 x 20W panels wired in series with the 24V battery supply will be required. Contact Centurion Systems (Pty) Ltd or your gate automation specialist for more details.
  • Page 37: Basic Maintenance

    – right hand value. This should indicate, 13.8V for the D5-Evo DOMESTIC and 27.6V for the D10 and D10 Turbo. Each charger has a red light (LED) to indicate mains supply.
  • Page 38 Gearbox Oil Level Check the oil level as described in the Lubrication section of the Installation Manual. Should the installation manual be unavailable, please refer to the online manuals on our website, www.centsys.co.za. Alternatively, contact Centurion Systems (Pty) Ltd or your gate automation specialist for assistance.
  • Page 39: Diagnostics

    Safety beam failure – if the safety beams are not operating the buzzer will emit five beeps periodically for 30 seconds (beams test circuit must be enabled) Contact Centurion Systems (Pty) Ltd or your gate automation specialist for assistance. Do not attempt to repair the unit yourself. Any work performed by unauthorised personnel may void the warranty.
  • Page 40: Specifications

    TABLE 1 1: Can operate off a solar supply, consult Centurion for assistance 2: 5Ah battery (can be upgraded for longer power failure autonomy) 3: Based on a push force of less than 50% of rated 4: Based on 25oC ambient temperature and unit not in direct sunlight...
  • Page 41: Month Product Warranty

    4. Has been repaired by any workshop and / or person NOT previously authorised by the manufacturer. 5. Has been repaired with components not previously tested, passed or authorised by Centurion Systems (Pty) Ltd, South Africa or one of its subsidiary companies. www.CentSys.com page 41...
  • Page 42 We will not be liable under this contract for any loss or damage caused by us or our employees or agents in circumstances where: 1. There has been a failure to install the product in accordance with the installation instructions provided by the manufacturer, or 2.
  • Page 43: Optional Extras

    Allow visitors to communicate with residents in order to gain access to the property. POLOphone Theft-resistant Cage Intercom Retro-installable steel cage that increases the resistance of the operator against theft D5-Evo Theft-resistant cage D10 Theft-resistant cage FIGURE 38 www.CentSys.com page 43...
  • Page 44 Connect with us on: facebook.com/CenturionSystems YouTube.com/CenturionSystems @askCenturion Subscribe to the newsletter: www.CentSys.com/Subscribe Call Centurion Systems (Pty) Ltd . South Africa Head Office: +27 11 699 2400 Call Technical Support: +27 11 699 2481 from 07h00 to 18h00 (UTC+2) Doc number: 0.07.A.0159_24022016 ENGLISH www.CentSys.com...

This manual is also suitable for:

D5-evo

Table of Contents

Save PDF