Yamaha HTR-4064 Service Manual page 54

Hide thumbs Also See for HTR-4064:
Table of Contents

Advertisement

RX-V471/HTR-4064
P2. PROTECTION HISTORY
This menu is used to display the history of protection
function.
All history of protection function will be erased by
pressing the "STRAIGHT" key.
*
Numeric values in the figure are given as reference
only.
S1. F/W UPDATE
Not for service.
S2. SET INFORMATION
The model name and destination of this unit are
displayed.
S2-1. MODEL
The model name of this unit is displayed.
Model name
A/D conversion value
(3.3 V=255)
54
P2-1. History 1 / 履歴 1
P 2 - 1
2 n d : P S 2
8 0
A/D conversion value when the protection function is activated.
(Reference voltage: 3.3 V=255)
プロテクション動作時の A/D 変換値
(基準値:3.3 V=255)
P2-2. History 2 / 履歴 2
P 2 - 2
1 s t : T m p 2
0
P2-3. History 3 / 履歴 3
P 2 - 3
3 t h : D C
1 3 5
P2-4. History 4 / 履歴 4
P 2 - 4
N o P r t
S 1 - 1
F / W U P D A T E ?
S 2 - 1
M D L : V 4 7 1
RX-V471
HTR-4064
0 − 10
11 − 33
P2. PROTECTION HISTORY
プロテクション履歴が表示されます。
STRAIGHT キーを押すとプロテクション履歴はすべ
て消去されます。
※ 図中の数値は参考例です。
S1. F/W UPDATE
サービスでは使用しません。
S2. SET INFORMATION
本機のモデル名、仕向け先が表示されます。
S2-1. MODEL
本機のモデル名が表示されます。
0
A/D conversion value / A/D 変換値
Model name / モデル名
V471 : RX-V471
H4064 : HTR-4064