[G] Right margin
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Open platen cover or RADF.
(3)
Press [FAX] to make a copy at the mode of A3/LD, 100%, Text/Photo and standard drawer of the
equipment (Refer to *).
* Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4)
Measure the blank area F at the right side of the copied image.
(5)
Check if the blank area F is within the range of 2±1.0 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in a value (acceptable values: 0 to 255))
Press the [ENTER] or the [INTERRUPT] button (stored in memory).
("100% A" is displayed.)
* The larger the adjustment value is, the wider the blank area at the right side becomes
(approx. 0.04 mm/step).
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
(Key in the code [432])
Feeding direction
Fig. 3-17
3 - 19
04/09
(Adjustment Mode)
[START]