VIESMANN VITOMAX 200-HS High pressure steam boiler Three-pass boiler Combustion output 3.8 to 18.2 MW Steam output 5 to 26 t/h Technical guide VITOMAX 200-HS Type M75A Oil/gas high pressure steam boiler Compliant with the requirements of the Pressure Equipment Directive 97/23/EC and the TRD regulations, in conjunction with the [German] trade association agreements.
2.13 Sizing the steam connector subject to the working pressure ........125 Boiler selection 3. 1 Schematic diagram to assist in selecting a boiler and determining parameters ..147 3. 2 Details for burner selection by the burner manufacturer ..........149 VIESMANN VITOMAX 200-HS...
The maximum combustion output varies subject to the required emission values and the fuel used. Check with the burner manufacturer. If using a downstream or on-site economiser. Because of production methods, the weight of the boiler can vary by up to 10 %. Average water level between pump ON and pump OFF. VIESMANN VITOMAX 200-HS...
The maximum combustion output varies subject to the required emission values and the fuel used. Check with the burner manufacturer. Flue gas hood and feedwater line are delivered separately. Because of production methods, the weight of the boiler can vary by up to 10 %. VIESMANN VITOMAX 200-HS...
Page 6
1.5 x combustion output in MW Flue gas volume - with ECO 100 10.7 12.4 15.0 18.4 23.4 30.6 35.1 - with ECO 200 10.9 12.5 15.0 18.6 23.8 31.0 35.5 Average water level between pump ON and pump OFF. VIESMANN VITOMAX 200-HS...
For Germany, the use of flame tube temperature limiters is regulated by the agreement of the trade associations 2003/1 as follows. FTÜ required: ■ for flame tube internal diameter > 1400 mm and/or ■ for combustion output > 12000 kW (oil combustion) > 15600 kW (gas combustion) VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 3.8 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 11
Flue gas temperature, fuel oil, max. 3.8 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 12
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 3.8 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 3.8 MW, with turbulators (2000 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 14
Flue gas temperature, fuel oil, max. 3.8 MW, with turbulators (2000 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 15
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 3.8 MW, with turbulators (2000 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 3.8 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 17
Flue gas temperature, fuel oil, max. 3.8 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 18
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 3.8 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 3.8 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 20
Boiler load in % Flue gas temperature, fuel oil, max. 3.8 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 21
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 3.8 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 4.5 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 23
Flue gas temperature, fuel oil, max. 4.5 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 24
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 4.5 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 4.5 MW, with turbulators (2000 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 26
Flue gas temperature, fuel oil, max. 4.5 MW, with turbulators (2000 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 27
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 4.5 MW, with turbulators (2000 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 4.5 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 29
Flue gas temperature, fuel oil, max. 4.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 30
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 4.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 4.5 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 32
Boiler load in % Flue gas temperature, fuel oil, max. 4.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 33
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 4.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 5.3 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 35
Flue gas temperature, fuel oil, max. 5.3 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 36
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 5.3 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 5.3 MW, with turbulators (2000 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 38
Flue gas temperature, fuel oil, max. 5.3 MW, with turbulators (2000 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 39
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 5.3 MW, with turbulators (2000 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 5.3 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 41
Flue gas temperature, fuel oil, max. 5.3 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 42
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 5.3 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 5.3 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 44
Boiler load in % Flue gas temperature, fuel oil, max. 5.3 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 45
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 5.3 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 6.4 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 47
Flue gas temperature, fuel oil, max. 6.4 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 48
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 6.4 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 6.4 MW, with turbulators (2000 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 50
Flue gas temperature, fuel oil, max. 6.4 MW, with turbulators (2000 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 51
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 6.4 MW, with turbulators (2000 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 6.4 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 53
Flue gas temperature, fuel oil, max. 6.4 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 54
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 6.4 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 6.4 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 56
Boiler load in % Flue gas temperature, fuel oil, max. 6.4 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 57
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 6.4 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 7.5 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 59
Flue gas temperature, fuel oil, max. 7.5 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 60
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 7.5 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 7.5 MW, with turbulators (1750 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 62
Flue gas temperature, fuel oil, max. 7.5 MW, with turbulators (1750 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 63
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 7.5 MW, with turbulators (1750 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 7.5 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 65
Flue gas temperature, fuel oil, max. 7.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 66
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 7.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 7.5 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 68
Boiler load in % Flue gas temperature, fuel oil, max. 7.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 69
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 7.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 9.0 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 71
Flue gas temperature, fuel oil, max. 9.0 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 72
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 9.0 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 9.0 MW, with turbulators (1000 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 74
Flue gas temperature, fuel oil, max. 9.0 MW, with turbulators (1000 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 75
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 9.0 MW, with turbulators (1000 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 9.0 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 77
Flue gas temperature, fuel oil, max. 9.0 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 78
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 9.0 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 9.0 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 80
Boiler load in % Flue gas temperature, fuel oil, max. 9.0 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 81
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 9.0 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 10.5 MW, standard (without turbulators), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 83
Flue gas temperature, fuel oil, max. 10.5 MW, standard (without turbulators) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 84
D Working pressure 11 bar G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max 10.5 MW, standard (without turbulators) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 10.5 MW, with turbulators (1250 mm), taking into account boiler radiation losses A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 86
Flue gas temperature, fuel oil, max. 10.5 MW, with turbulators (1250 mm) A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 18 bar C Working pressure 8 bar G Working pressure 23 bar D Working pressure 11 bar VIESMANN VITOMAX 200-HS...
Page 87
G Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 10.5 MW, with turbulators (1250 mm) A Working pressure 2 bar D Working pressure 11 bar G Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 10.5 MW, without turbulators, with ECO 100, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 89
Flue gas temperature, fuel oil, max. 10.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 18 bar C Working pressure 11 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 90
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 10.5 MW, without turbulators, with ECO 100 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 10.5 MW, without turbulators, with ECO 200, taking into account boiler radiation losses A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 92
Boiler load in % Flue gas temperature, fuel oil, max. 10.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
Page 93
A Working pressure 5 bar F Working pressure 23 bar Boiler load in % Flue gas pressure drop, fuel oil, max. 10.5 MW, without turbulators, with ECO 200 A Working pressure 5 bar F Working pressure 23 bar VIESMANN VITOMAX 200-HS...
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 95
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 96
Flue gas pressure drop, fuel oil, max 12.3 MW, standard (without turbulators) 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar F Working pressure 19 bar VIESMANN VITOMAX 200-HS...
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 98
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 99
Flue gas pressure drop, fuel oil, max. 12.3 MW, with turbulators (1000 mm) 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar F Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 12.3 MW, without turbulators, with ECO 100, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 101
Flue gas temperature, fuel oil, max. 12.3 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 102
Boiler load in % Flue gas pressure drop, fuel oil, max. 12.3 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 12.3 MW, without turbulators, with ECO 200, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 104
Flue gas temperature, fuel oil, max. 12.3 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 105
Boiler load in % Flue gas pressure drop, fuel oil, max. 12.3 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 107
1 Boiler load limit to EN 12953 for fuel oil EL D Working pressure 11 bar A Working pressure 2 bar E Working pressure 14 bar B Working pressure 5 bar F Working pressure 19 bar C Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 108
Flue gas pressure drop, fuel oil, max 14.0 MW, standard (without turbulators) 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar F Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 14.0 MW, without turbulators, with ECO 100, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 110
Flue gas temperature, fuel oil, max. 14.0 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 111
Boiler load in % Flue gas pressure drop, fuel oil, max. 14.0 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 14.0 MW, without turbulators, with ECO 200, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 113
Flue gas temperature, fuel oil, max. 14.0 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 14 bar B Working pressure 8 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Page 114
Boiler load in % Flue gas pressure drop, fuel oil, max. 14.0 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar E Working pressure 19 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 14.0 MW, standard (without turbulators), taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar D Working pressure 11 bar B Working pressure 5 bar E Working pressure 16.5 bar VIESMANN VITOMAX 200-HS...
Page 116
Flue gas temperature, fuel oil, max. 14.0 MW, standard (without turbulators) 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar D Working pressure 11 bar B Working pressure 5 bar E Working pressure 16.5 bar VIESMANN VITOMAX 200-HS...
Page 117
Flue gas pressure drop, fuel oil, max 14.0 MW, standard (without turbulators) 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 8 bar A Working pressure 2 bar E Working pressure 16.5 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 14.0 MW, without turbulators, with ECO 100, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 16.5 bar B Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 119
Flue gas temperature, fuel oil, max. 14.0 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 16.5 bar B Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 120
Boiler load in % 76.9 Flue gas pressure drop, fuel oil, max. 14.0 MW, without turbulators, with ECO 100 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar D Working pressure 16.5 bar VIESMANN VITOMAX 200-HS...
Boiler efficiency, fuel oil, max. 14.0 MW, without turbulators, with ECO 200, taking into account boiler radiation losses 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 16.5 bar B Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 122
Flue gas temperature, fuel oil, max. 14.0 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL C Working pressure 11 bar A Working pressure 5 bar D Working pressure 16.5 bar B Working pressure 8 bar VIESMANN VITOMAX 200-HS...
Page 123
Boiler load in % 76.9 Flue gas pressure drop, fuel oil, max. 14.0 MW, without turbulators, with ECO 200 1 Boiler load limit to EN 12953 for fuel oil EL A Working pressure 5 bar D Working pressure 16.5 bar VIESMANN VITOMAX 200-HS...
Boiler selection diagrams (cont.) 2.11 Saturated steam enthalpy Saturated steam pressure (positive pressure) in bar A Saturated steam enthalpy B Saturated steam temperature 2.12 Feedwater enthalpy Feedwater temperature in °C VIESMANN VITOMAX 200-HS...
A Internal diameter DN 150 E Internal diameter DN 350 B Internal diameter DN 200 F Internal diameter DN 400 C Internal diameter DN 250 G Internal diameter DN 450 D Internal diameter DN 300 H Internal diameter DN 500 VIESMANN VITOMAX 200-HS...
Page 126
A Internal diameter DN 150 E Internal diameter DN 350 B Internal diameter DN 200 F Internal diameter DN 400 C Internal diameter DN 250 G Internal diameter DN 450 D Internal diameter DN 300 H Internal diameter DN 500 VIESMANN VITOMAX 200-HS...
Page 127
A Internal diameter DN 150 E Internal diameter DN 350 B Internal diameter DN 200 F Internal diameter DN 400 C Internal diameter DN 250 G Internal diameter DN 450 D Internal diameter DN 300 H Internal diameter DN 500 VIESMANN VITOMAX 200-HS...
Page 128
Steam connector size, working pressure 5 bar A Internal diameter DN 150 E Internal diameter DN 350 B Internal diameter DN 200 F Internal diameter DN 400 C Internal diameter DN 250 G Internal diameter DN 450 D Internal diameter DN 300 VIESMANN VITOMAX 200-HS...
Page 129
Steam connector size, working pressure 6 bar A Internal diameter DN 125 E Internal diameter DN 300 B Internal diameter DN 150 F Internal diameter DN 350 C Internal diameter DN 200 G Internal diameter DN 400 D Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 130
Steam connector size, working pressure 7 bar A Internal diameter DN 125 E Internal diameter DN 300 B Internal diameter DN 150 F Internal diameter DN 350 C Internal diameter DN 200 G Internal diameter DN 400 D Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 131
Steam connector size, working pressure 8 bar A Internal diameter DN 125 D Internal diameter DN 250 B Internal diameter DN 150 E Internal diameter DN 300 C Internal diameter DN 200 F Internal diameter DN 350 VIESMANN VITOMAX 200-HS...
Page 132
Steam connector size, working pressure 9 bar A Internal diameter DN 100 E Internal diameter DN 250 B Internal diameter DN 125 F Internal diameter DN 300 C Internal diameter DN 150 G Internal diameter DN 350 D Internal diameter DN 200 VIESMANN VITOMAX 200-HS...
Page 133
Steam connector size, working pressure 10 bar A Internal diameter DN 100 E Internal diameter DN 250 B Internal diameter DN 125 F Internal diameter DN 300 C Internal diameter DN 150 G Internal diameter DN 350 D Internal diameter DN 200 VIESMANN VITOMAX 200-HS...
Page 134
Steam connector size, working pressure 11 bar A Internal diameter DN 100 D Internal diameter DN 200 B Internal diameter DN 125 E Internal diameter DN 250 C Internal diameter DN 150 F Internal diameter DN 300 VIESMANN VITOMAX 200-HS...
Page 135
Steam connector size, working pressure 12 bar A Internal diameter DN 100 D Internal diameter DN 200 B Internal diameter DN 125 E Internal diameter DN 250 C Internal diameter DN 150 F Internal diameter DN 300 VIESMANN VITOMAX 200-HS...
Page 136
Steam connector size, working pressure 13 bar A Internal diameter DN 100 D Internal diameter DN 200 B Internal diameter DN 125 E Internal diameter DN 250 C Internal diameter DN 150 F Internal diameter DN 300 VIESMANN VITOMAX 200-HS...
Page 137
(cont.) Steam velocity in m/s Steam connector size, working pressure 14 bar A Internal diameter DN 100 D Internal diameter DN 200 B Internal diameter DN 125 E Internal diameter DN 250 C Internal diameter DN 150 VIESMANN VITOMAX 200-HS...
Page 138
Steam connector size, working pressure 15 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 139
Steam connector size, working pressure 16 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 140
Steam connector size, working pressure 17 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 141
Steam connector size, working pressure 18 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 142
Steam connector size, working pressure 19 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 143
Steam connector size, working pressure 20 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 144
Steam connector size, working pressure 21 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 F Internal diameter DN 250 VIESMANN VITOMAX 200-HS...
Page 145
(cont.) Steam velocity in m/s Steam connector size, working pressure 22 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 VIESMANN VITOMAX 200-HS...
Page 146
(cont.) Steam velocity in m/s Steam connector size, working pressure 23 bar A Internal diameter DN 80 D Internal diameter DN 150 B Internal diameter DN 100 E Internal diameter DN 200 C Internal diameter DN 125 VIESMANN VITOMAX 200-HS...
= 11131 kW tive boiler, from page 10 boiler load 11131 kW ÷ 12700 kW = 87.6 % Repeat, if required The maximum steam output is subject to the permissible combustion output, operating conditions and achievable boiler efficiency. VIESMANN VITOMAX 200-HS...
Page 148
4.2.2, paragraph 2. To select a safety valve, please use the pricelist. It may be more economical to install a heat exchanger downstream. By using a heat exchanger it may be possible to install the next boiler size down. VIESMANN VITOMAX 200-HS...
Need help?