Page 3
GENERAL PRECAUTIONS REGARDING THE SERVICE FOR e-STUDIO165/167/205/207/237 The installation and service should be done by a qualified service technician. 1) Transportation/Installation When transporting/installing the equipment, remove the drawer, employ two persons and be sure to hold the positions as shown in the figure.
Page 4
If these parts are short-circuited and their functions become ineffective, they may result in fatal accidents such as burnout. Do not allow a short-circuit or do not use the parts not recommended by Toshiba TEC Corporation. 4) Cautionary Labels During servicing, be sure to check the rating plate and cautionary labels such as “Unplug the power cable during service”, “CAUTION.
Page 7
6.1.2 Writing the data to the download jig (PWA-DWNLD-350-JIG) ......... 6-7 6.1.3 K-PWA-DLM-320...................... 6-9 6.2 Firmware Updating with TOSHIBA Viewer (e-STUDIO165/205 only) ....... 6-10 6.3 Firmware Updating with USB Storage Device (When GA-1190/GA-1200 is installed)..6-13 6.4 Firmware Updating with Software Update Tool ..............6-19 6.4.1 General Description....................
SPECIFICATIONS / ACCESSORIES / OPTIONS / SUPPLIES Specifications When the value is different among e-STUDIO165/167, 205/207 and 237, the value for e-STUDIO205/207 is shown by [ ] and the value for e-STUDIO237 is shown by { }. Copy process Indirect electrophotographic process (dry)
PM cycle of each unit. e-STUDIO165/167:every 72,000 sheets e-STUDIO205/207/237:every 90,000 sheets 2. Value under “Replacement” indicates the replacement cycle for e-STUDIO165/167/ e-STUDIO205/207/237. 3. The replacement cycle of the parts in the feeding section equals to the number of sheets fed from each paper source.
P. 6-1 "6.1 Firmware Updating with Download Jig" • Updating with PC connected P. 6-10 "6.2 Firmware Updating with TOSHIBA Viewer (e-STUDIO165/205 only)" • Updating with the USB Storage Device (When GA-1190/GA-1200 is installed) P. 6-13 "6.3 Firmware Updating with USB Storage Device (When GA-1190/GA-1200 is installed)"...
Ensure that the firmware to be updated is for the intended model. • If the firmware for e-STUDIO167/207/237 is updated on e-STUDIO165/205 by mistake, a C94 error message appears when the power is turned OFF and then back ON after the update.
Firmware Updating with TOSHIBA Viewer (e-STUDIO165/205 only) Using the TOSHIBA Viewer, you can download the firmware from the PC to this copier for updating. Important: • Data to be downloaded should be stored in the same drive as the TOSHIBA Viewer program.
• Store the model specific folder in the root directory of the USB storage device. • Distinguish between the firmware for e-STUDIO165/205 and that for e-STUDIO167/207/237 by its model specific folder name. • The USB storage device complied with USB1.1 and USB2.0 can be used for updating. How- ever, the update is performed in the speed of USB1.1 when the device complied with USB2.0...
Page 286
• When updating the firmware for the Controller ROM (GA-1190) or the Scanner ROM (GA- 1200), change the model specific folder name to “165_205” if the model is e-STUDIO165/205. Change it to “167_237” if the model is e-STUDIO167/207/237. Since the model specific folder to be detected differs depending on the controller ROM ver-...
Only installation by hardware wizard can recognize e-STUDIO165/167/205/207/237. If the TOSHIBA Viewer USB driver is already installed, the software update tool USB driver can- not be. Delete the corresponding COM port on the Device Manager window and then start the installation of the software update tool USB driver.
Page 293
Select the "e-STUDIO165/205/167/207/237" check box in the Product Name field. Fig. 6-33 Confirm that both the "Program" and the "Function" check boxes in the Download Area field are cleared, and then click [ALL]. Fig. 6-34 Note: Note: In e-STUDIO165/167/205/207/237, the download area has three selections; "Program (program data)", "Function (function data)"...