Error #S1-3212 Turn Off Then On; Install Wireless Nic - Samsung SCX-472 series Service Manual

Mono laser mfp
Hide thumbs Also See for SCX-472 series:
Table of Contents

Advertisement

► Error Code
S1–3212
► Error message

Error #S1-3212 Turn off then on

► Symptom
The Motor Control chip on the main board does not work normally.
► Troubleshooting method
1) Turn the machine off then on.
2) If the problem persists, replace the main board.
► Error Code
S1–5221
► Error message

Install wireless NIC

► Symptom
The communication error between the main board and the wireless board has occurred.
► Troubleshooting method
Check if the connection between the main board and the wireless board is normal.
If the connection is OK, replace the part in this order. (Flat cable -> Wireless board -> Main board)