Status Codes - Amana AMVM97 Service Instructions Manual

Hide thumbs Also See for AMVM97:
Table of Contents

Advertisement

Status Codes

O n
A
b 0
b 1
b 2
b 3
b 4
b 5
b 6
b 7
b 9
C
C 1
C 2
d
d 0
d 1
d 2
d 4
dF
E 0
E 1
E 2
E 3
E 4
E 5
E 6
E 7
E 8
E 9
E A
E C
E d
E F
F
F t
H
HI
IF
P
P 1
P 2
50
66
NO POWER
NORMAL OPERATION
INDICATES AIRFLOW, FOLLOWED BY CFM
BLOWER MOTOR NOT RUNNING
BLOWER COMMUNICATION ERROR
BLOWER HP MIS-MATCH
BLOWER MOTOR OPERATING IN POWER, TEMPERATURE, OR SPEED LIMIT
BLOWER MOTOR CURRENT TRIP OR LOST ROTOR
BLOWER MOTOR LOCKED ROTOR
BLOWER OVER/UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP
INCOMPLETE PARAMETERS SENT TO MOTOR
LOW INDOOR AIRFLOW
CLIMATETALK COMPRESSOR COOLING / CONVENTIONAL COMPRESSOR COOLING
WHEN 1-STAGE COMPRESSOR IS SET UP
LOW STAGE COOL
HIGH STAGE COOL
CLIMATETALK COMPRESSOR COOLING WITH DEHUMIFICATION / CONVENTIONAL
COMPRESSOR COOLING WITH DEHUMIDIFICATION WHEN 1-STAGE
COMPRESSOR IS SET UP
DATA NOT YET ON NETWORK
CONVENTIONAL 1-STAGE COMPRESSOR COOLING WITH DEHUMIDIFICATION WHEN
2-STAGE COMPRESSOR IS SET UP
CONVENTIONAL 2-STAGE COMPRESSOR COOLING WITH DEHUMIDIFICATION WHEN
2-STAGE COMPRESSOR IS SET UP
INVALID MEMORY CARD DATA
DEFROST DEMAND
LOCKOUT DUE TO EXCESSIVE RETRIES OR RECYCLES
LOW STAGE PRESSURE SWITCH STUCK CLOSED AT START OF HEATING CYCLE
LOW STAGE PRESSURE SWITCH STUCK OPEN
OPEN HIGH LIMIT SWITCH
FLAME DETECTED WHEN NO FLAME SHOULD BE PRESENT
OPEN FUSE
LOW FLAME SIGNAL
IGNITER FAULT OR IMPROPER GROUNDING
HIGH STAGE PRESSURE SWITCH STUCK CLOSED AT START OF HEATING CYCLE
HIGH STAGE PRESSURE SWITCH STUCK OPEN
REVERSED 115 VAC POLARITY
INDUCER MOTOR OVERCURRENT FAULT
ROLLOUT SWITCH OPEN
AUXILIARY INPUT OPEN
CONTINUOUS FAN
FIELD TEST MODE
INDICATES GAS HEAT, FOLLOWED BY PERCENTAGE OF DEMAND
HIGH HEAT = 100%
INTERNAL FAULT
CLIMATETALK COMPRESSOR HEATING / CONVENTIONAL COMPRESSOR HEATING
WHEN 1-STAGE COMPRESSOR IS SET UP
CONVENTIONAL 1-STAGE COMPRESSOR HEATING
WHEN 2-STAGE COMPESSOR IS SET UP
CONVENTIONAL 2-STAGE COMPRESSOR HEATING
WHEN 2-STAGE COMPESSOR IS SET UP
% OF HIGH HEAT

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMVM97 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Gcvm97Acvm97Gmvm97