Download Print this page
Amana AMVM97 Manual

Amana AMVM97 Manual

Modulating, variable-speed ecm gas furnace up to 98% afue
Hide thumbs Also See for AMVM97:

Advertisement

H
i
: 60,000-120,000 Btu/
eating
nput
Standard Features
• ComfortNet™ Communicating System compatible
• Heavy-duty stainless-steel tubular heat exchanger
• Stainless-steel secondary heat exchanger
• Self-calibrating modulating gas valve
auto-configure for each installation
• Durable Silicon Nitride igniter
• Quiet two-speed induced draft blower
• Uses ComfortNet™ communicating,
two-stage or single-stage thermostats
• Self-diagnostic control board with constant memory
fault code history output to a dual 7-segment display
• Color-coded low-voltage terminals with provisions
for electronic air cleaner and humidifier
• Efficient and quiet variable-speed airflow system gently
ramps up or down according to heating or cooling demand
• Multiple continuous fan speed
options offer quiet air circulation
• Auto-Comfort and enhanced
dehumidification modes available
• All models comply with California 40 ng/J
Low NOx emissions standard
SS-AMVM97
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
AMVM97 / ACVM97
M
H
odulating
Cabinet Features
• Designed for multi-position installation:
AMVM97: upflow, horizontal left or right
ACVM97: downflow, horizontal left or right
• Certified for direct vent (2-pipe)
or non-direct vent (1-pipe)
• Easy-to-install top venting
with optional side venting
• Convenient left or right connection
for gas and electrical service
• Cabinet air leakage (Q
• Heavy-gauge steel cabinet with durable finish
• Fully insulated heat exchanger
and blower section
• Airtight solid bottom or side return
with easy-cut tabs for effortless removal
in bottom air-inlet applications
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger
Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and
the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not
required in California or Québec.
www.amana-hac.com
, V
ariable
eCM g
F
aS
u
98% aFue
p to
Contents
Nomenclature ........................................ 2
Product Specifications ........................... 3
Dimensions ............................................ 4
Airflow Specifications ............................ 6
Wiring Diagram .................................... 11
Accessories .......................................... 12
) ≤ 2%
Leak
-S
peed
urnaCe
10/17
Supersedes 2/17

Advertisement

loading
Need help?

Need help?

Do you have a question about the AMVM97 and is the answer not in the manual?

Questions and answers

Summary of Contents for Amana AMVM97

  • Page 1: Table Of Contents

    • Auto-Comfort and enhanced dehumidification modes available • All models comply with California 40 ng/J Low NOx emissions standard * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-AMVM97 www.amana-hac.com 10/17 Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes 2/17...
  • Page 2: Nomenclature

    Nomenclature 7,8,9 13,14 Brand Engineering A - Amana® Brand Major / Minor Revisions * Not used for inventory control. Configuration M - Upflow/Horizontal N - Low NOx C - Downflow/Horizontal Cabinet Width Motor B - 17½” C - 21" V - Variable Speed ECM / ComfortNet D - 24½" E - Multi-Speed ECM Maximum CFM S - Single Speed 2 - 800 CFM 4 - 1600 CFM Gas Valve 3 - 1200 CFM 5 - 2000 CFM M - Modulating...
  • Page 3: Product Specifications

    Product Specifications AMVM97 AMVM97 AMVM97 AMVM97 AMVM97 ACVM97 ACVM97 ACVM97 ACVM97 0603BNA 0803BNA 0804CNA 1005CNA 1205DNA 0603BNA 0803BNA 0804CNA 1005CNA Heating Data High Fire Input¹ 60,000 80,000 80,000 100,000 120,000 60,000 80,000 80,000 100,000 High Fire Output¹ 58,800 77,600 78,400 97,000 116,400 58,200 77,600...
  • Page 4: Dimensions

    AMVM97 Dimensions Discharge Discharge 28¾ 6½ ¾ 2¾ 6½ ¾ Air Intake 2⅝ 1⅞ 2" Pipe 19½ Center Dimple Vent/ Flue Pipe Left-Side Alternate For Alternate 2" PVC Drain Trap Vent/ Flue Air Intake Pipe ¾ Exterior Holes 3" Location...
  • Page 5 18⅛" 17½" 18" 19½" ACVM971005CNA 21" 28⅞" 34½" 21" 18⅛" 17½" 18" 19½" iniMuM learanCes to oMBustiBle aterials Position Sides Rear Front Bottom Flue Downflow 0" 0" 3" 0" 1" Horizontal 6" 0" 3" 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. SS-AMVM97 www.amana-hac.com...
  • Page 6: Airflow Specifications

    AMVM97 Airflow Data AMVM970603BNA AMVM970603BNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% Normal Normal Plus 10% Plus 10% 1,048...
  • Page 7 AMVM97 Airflow Data (cont.) AMVM971005CNA AMVM971005CNA Cooling Speed Heating Speed (@ .1" - .8" w.c. ESP) (@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F) High-Stage Low-Stage High-Stage Rise Adjust Adjust (°F) Minus 10% Minus 10% 1,636 Normal Normal 1,818...
  • Page 8 Normal Normal 1,146 Plus 10% Plus 10% 1,261 Minus 10% Minus 10% 1,130 Normal Normal 1,256 Plus 10% 1,093 Plus 10% 1,382 Minus 10% 1,059 Minus 10% 1,214 Normal 1,177 Normal 1,349 Plus 10% 1,295 Plus 10% 1,484 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. www.amana-hac.com SS-AMVM97...
  • Page 9 Minus 10% 1,693 Normal 1,766 1,185 Normal 1,881 Plus 10% 1,943 1,304 Plus 10% 2,069 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. iniMuM ilter izes ACVM97 ACVM97 ACVM97 ACVM97 0603BNA 0803BNA 0804CNA 1005CNA (2) 14 x 20 or Filter Sizes (in²) (Qty) (2) 10 x 20 or (1) 16 x 25 (top return) (1) 20 x 25 (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS-AMVM97 www.amana-hac.com...
  • Page 10 Temperature Rise Range Chart www.amana-hac.com SS-AMVM97...
  • Page 11: Wiring Diagram

    MANUAL RESET ROLLOUT LIMIT CONTROLS (11) DEHUM FRONT COVER (10) PRESS. VALVE SWITCH GND (4) TR (9) GND (4) + VDC (1) INDOOR RX (2) CIRCULATOR TX (3) BLWR MICRO INTEGRATED CONTROL MODULE (ON SOME MODELS) GR GREEN SS-AMVM97 www.amana-hac.com...
  • Page 12: Accessories

    Accessories AMVM97 AMVM97 AMVM97 AMVM97 AMVM97 Model Description 0603BNA 0803BNA 0804CNA 1005CNA 1205DNA CTK04 ComfortNet-Compatible Control √ √ √ √ √ CVENT-2 Concentric Vent Kit (2") √ √ √ √ √ CVENT-3 Concentric Vent Kit (3") √ √ √ √ √ RF000142 Drain Kit -Horizontal Left Vertical Flue √ √ √ √...

This manual is also suitable for:

Acvm97
Save PDF