Tranquility Medium Temperature Water-to-Water (TMW) Series Table of Contents Model Nomenclature Storage Pre-Installation Physical Data Dimensional Data Water Connection Installation Ground Loop Applications 9-10 Ground Water Applications 11-12 Water Quality Standards Load Plumbing Installation Hot Water Generator 15-16 Electrical - Line Voltage Electrical - Low Voltage Wiring 18-19 Electrical - Accessories...
Page 2
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v.
ClimateMaster Geothermal Heat Pump Systems R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v.
Equipment should be stored in its original packaging in a clean, dry area. Store units in an upright position at all times. The stack limit for TMW036, 060 and 120 is three. Unit Protection Cover units on the job site with either shipping packaging, vinyl fi...
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v. : 1 0 J a n . , 2 0 1 3 TMW036 - 120 Unit Dimensional Data Notes: 1.
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v.
Page 12
The fi eld installed high pressure switch shall have a cut-out pressure of 300 psig and a cut-in pressure of 250 psig. This pressure switch can be ordered from ClimateMaster with a 1/4” internal fl are connection as part number 39B0005N02. CAUTION! CAUTION! Refrigerant pressure activated water regulating valves should never be used with ClimateMaster equipment.
Rev.: 3/22/2012 The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. When water properties are outside of those requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water. Failure to do so will void the warranty for the coaxial heat exchanger.
24VAC external solenoid valve. Figures 6 or 7 illustrate typical slow closing water control valve wiring for Taco 500 series (ClimateMaster P/N AVM…) and Taco SBV series valves. Slow closing valves take approximately 60 seconds to open (very little water will fl ow before 45 seconds).
fi rst started in the heating mode, when possible. Table 8: Coax Water Pressure Drop This will allow liquid refrigerant to fl ow through the TMW036-120 fi lter-drier before entering the TXV, allowing the Pressure Drop PSI fi lter-drier to catch any debris that might be in the Model GPM 30°F...
Page 27
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v.
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v. : 1 0 J a n . , 2 0 1 3 Operating Pressures Table 9 TMW036-120 (TMW120 Per Circuit) (60 Hz I-P Units) Cooling Source Source...
Page 29
R e s i d e n t i a l Tr a n q u i l i t y W a t e r- t o - W a t e r ( T M W ) S e r i e s - H F C - 4 1 0 A R e v. : 1 0 J a n . , 2 0 1 3 Operating Pressures Table 10 TMW036-120 (TMW120 Per Circuit) (60 Hz I-P Units) Heating Source Source...
ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi...
Need help?
Do you have a question about the TMW036 and is the answer not in the manual?
Questions and answers