Installation; Space Requirements; Installation Process - Mitsubishi Electric E1032 Installation Manual

Operator terminal
Hide thumbs Also See for E1032:
Table of Contents

Advertisement

2

Installation

2.1 Space Requirements

– Installation plate thickness: 1.5 - 7.5 mm (0.06 - 0.3 inch)
– Space requirements when installing the operator terminal:
187 mm
(7.36 inch)
50 mm
(2.0 inch)
Caution
The openings on the enclosure are for air convection. Do not cover these
openings.

2.2 Installation Process

1. Unpack and check the delivery. If damage is found, notify the supplier
Note:
Place the operator terminal on a stable surface during installation.
Dropping it or letting it fall may cause damage.
2. Place the panel cut out where the operator terminal is to be situated, draw along
the outer sides of the holes and cut according to the markings. If access to the
text strips is needed, add extra space at the left side.
Mitsubishi Electric, MA00816
100 mm
(4.0 inch)
50 mm
(2.0 inch)
100 mm
(4.0 inch)
202 mm
(7.95 inch)
Panel cut out 166 x 149 mm
(6.54 x 5.87 inch)
x 4
For text strip
7.0 mm
(0.28 inch)
100 mm
(4.0 inch)
56.9 mm
(2.24 inch)
.
Installation
7