Precautions For Connection - Mitsubishi Electric DX-ZD6UE Installation And Operation Manual

Hdd extension unit
Table of Contents

Advertisement

Notice
When connecting 5 or more HDD extension units (with 2 HDDs mounted on each unit) to the digital recorder, you are
recommended to use USB cable as illustrated below to prevent recognition error of digital recorder due to different
start-up times among HDDs.
Furthermore, before you start operation or when the power restores from a power failure, check that the HDDs are
recognized correctly even when a small number of HDD extension units are connected.
The EXTERNAL CONTROL switch is set to ON by default. In this status, this unit does not work even though you
connet the power cord and set the MAIN switch to ON.
Connect this unit and the recorder as "Connection to link the power supply of the recorder and this unit" on
10.
Tips
The available number of HDD extension units to be connected varies depending on the recorder connected. Check the
specification of the recorder.
You cannot connect 6 or more HDD extension units in series using serial bus.
The number of serial bus ports varies depending on the digital recorder connected. For stable recording, it is
recommended to use the ports of the recorder as many as possible to avoid branch connection of the extension units.

Precautions for connection

Digital recorder
IN
IN
This unit
This unit
OUT
OUT
IN
IN
IN
This unit
This unit
This unit
OUT
OUT
OUT
IN
IN
IN
This unit
This unit
This unit
OUT
OUT
OUT
IN
IN
IN
This unit
This unit
This unit
* When 2 serial bus ports are used.
IN
This unit
OUT
IN
This unit
OUT
IN
This unit
page
9

Advertisement

Table of Contents
loading

Table of Contents