Mitsubishi Electric DX-PC for View User Manual page 24

Remote operation software option for digital recorder
Table of Contents

Advertisement

User's Manual
Remote Site: Configures the connection list for remote access.
 Add: Click the Add button and enter the information about the remote site you want to add.
20
– Reference Group: The site should be assigned to a
Reference Group for effective management of multiple
remote sites. Click the Add button to create a new reference
group.
– Device Setup: Select the system of the remote site to
register. When registering an IP camera, select IP Camera.
– Remote Site Setup: Select PC Based DVR when
registering a DVR at the remote site that is PC based. Enter
a site name and the IP address of the remote site (modem
telephone number for dial-up connections), acquired from
your network administrator. Click the Port... button to set
up the IP port number of each program. The IP port number
should match the value set during the network setup of the
remote DVR. If the remote system version does not allow
you to set the IP port numbers, use the following values:
"8200" for Admin, "8016" for Watch, "10019" for
Search, and "8116" ("8115" for a PC-based DVR) for
Audio. Select the number of cameras at the remote site.
For example, selecting "8" from the list when registering
a 16-channel DVR displays video of the first 8 channels
on the screen.