Troubleshooting - MacroAir Technologies AirVolution 550 Installation Manual

Table of Contents

Advertisement

Troubleshooting

It is recommended to wire the fan and the touchpad remote prior to turning on the power to the
fan. If the fan is not operable, but the touchpad remote is lighting up, cycle power to the fan.
If cycling the power did not resolve this issue, go to the fault code screen (reference page 47) and
check to see if there is a code present.
Fault Code Causes and Possible Solutions
Code
Name
Supply Voltage High
1000
Warning
Supply Voltage Low
1001
Warning
Supply Voltage High
1002
Fault
Supply Voltage Low
1003
Fault
Phase Current A High
1004
Fault
Phase Current B High
1005
Fault
Phase Current C High
1006
Fault
Motor Temperature
1007
High Warning
Motor Temperature
1008
High Fault
© 2015 MacroAir Technologies
Factory
Code Type
Setting
Warning 425V DC
Warning
80V DC
Auto-
450V DC
Reset
Halt
40V DC
Auto-
Reset
Auto-
Reset
Auto-
Reset
Warning
100C
Auto-
110C
Reset
Toll Free: 866 668 3247
Description
Symptoms
The controller
monitors the bus
voltage to verify it's
below the threshold
The controller
monitors the bus
voltage to verify it's
above the threshold
The controller
monitors the bus
voltage to verify it's
Fan stops suddenly
below the threshold
on deceleration
and will disable the
fan if it is exceeded
The controller
monitors the bus
voltage to verify it's
Fan stops suddenly
above the threshold
on acceleration
and will disable the
fan if it is exceeded
Current not
regulating
Grunting, vibration
sounds
Sudden shutdown
The controller
multiplies the current
torque command by
0.5 when the motor
reaches 100C. There
is no hysteresis on
Fan runs slower
this value. It goes
back to full speed
when the temperature
falls below the
warning value.
Fan stops
Fax: 909 890 2313
Troubleshooting Tips
Expected behavior
when the fan is
slowing to a stop
Verify incoming AC
power
Verify incoming AC
power
Check wiring
Verify incoming AC
power
Check wiring
Verify motor
parameters
Perform Power
Calibration
Return to Factory,
damaged drive, motor
short/bad wiring,
drive in danger of
permanent damage
Operating Ambient
temperature
exceeded
Motor thermistor
out of spec. and /or
damaged
w w w.macroairfans.com
Rev. Date 090415