Mitsubishi Electric PAR-FL31MA Instruction Manual

Mitsubishi Electric PAR-FL31MA Instruction Manual

Wireless remote controller

Advertisement

Mitsubishi Electric Building
Air Conditioning Control System
Wireless Remote Controller PAR-FL31MA
INSTRUCTION BOOK
• Read this manual thoroughly before using the remote controller.
• For those who carry out the installation work.
After completing all the work, explain how to operate the remote controller to the customer referring to this manual, then hand the manual over to him.
ANWEISUNGSHANDBUCH
• Lesen Sie dieses Handbuch gründlich durch, bevor Sie die Fernbedienung benutzen.
• Hinweis für die mit der Installation beauftragten Personen:
Erläutern Sie dem Kunden nach Abschluß der Installationsarbeiten anhand dieses Handbuchs den Gebrauch der Fernbedienung und händigen Sie das
Handbuch danach dem Kunden aus.
MANUEL D'UTILISATION
• Veuillez lire attentivement le présent manuel avant d'utiliser la télécommande.
• Pour les personnes chargées des travaux d'installation.
Lorsque les travaux sont terminés, expliquer le fonctionnement de la télécommande au client en se reportant au présent manuel puis lui remettre le manuel.
INSTRUCTIEHANDLEIDING
• Lees deze handleiding zorgvuldig door voordat u de afstandsbedieningseenheid gebruikt.
• Voor de installateur:
Wanneer u klaar bent, gelieve de klant de werking van de afstandsbedieningseenheid met gebruik van deze handleiding uit te leggen. Overhandig de
handleiding daarna aan de klant.
LIBRETTO ISTRUZIONI
• Prima di utilizzare il telecomando leggere attentamente il presente manuale.
• Per gli addetti all'installazione:
Dopo aver completato il lavoro, spiegare al cliente il funzionamento del telecomando facendo riferimento al presente manuale, che va quindi consegnato al
cliente.
LIBRO DE INSTRUCCIONES
• Lea este manual con detenimiento antes de utilizar el controlador remoto.
• Para los técnicos instaladores:
Una vez terminada la instalación, explique al cliente cómo utilizar el controlador remoto con ayuda del presente manual. A continuación, entréguele el
manual.
˚C
PM
NOT AVAILABLE
ON/OFF
TEMP.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PAR-FL31MA

  • Page 1 Mitsubishi Electric Building Air Conditioning Control System Wireless Remote Controller PAR-FL31MA ˚C NOT AVAILABLE ON/OFF TEMP. INSTRUCTION BOOK • Read this manual thoroughly before using the remote controller. • For those who carry out the installation work. After completing all the work, explain how to operate the remote controller to the customer referring to this manual, then hand the manual over to him.
  • Page 2: Safety Precautions

    1. Safety Precautions • Be sure to read these Safety precautions thoroughly and install the remote controller correctly. • The following two symbols are used to denote dangers that may be caused by incorrect use. They are classified according to the degree of danger. WARNING: This symbol denotes what could lead to serious injury or death if you misuse the controller.
  • Page 3: Checking The Contents Of The Package

    Do not use for other special purposes. • The controller has been designed for use with the MITSUBISHI Electric Building Air Condition- ing Control System only. Do not use for other purposes such as controlling other air condition- ers.
  • Page 4: Table Of Contents

    3. Name of Component • Wireless Remote Controller ∗ The following example is for explanatory purposes only and shows the operating section when all the LCD displays are lit. It differs from the actual display. The LCD will remain dark while the remote controller is not in operation.
  • Page 5: Display

    • Signal Receiving Unit (Sold separately) ON/OFF lamp (lit when unit is operating; unlit when unit is not operating) ON/OFF Emergency operation In cases where the remote control unit does not operate properly, use either the button on the wire- COOL HEAT less remote control signal receiver to toggle the unit on or...
  • Page 6: Vane

    4. Before Operation 4-1. Setting the DIP-Switch It is necessary to set the DIP switches before using this remote control unit. ∗ The remote control unit will not operate properly unless the DIP switch settings are correct. ∗ Customers should not perform the settings themselves, but rather should request that the settings been made during installation by qualified personnel.
  • Page 7: Inserting Batteries

    4-2. Inserting Batteries 1 Remove the battery cover and insert the bat- 2 Replace the battery cover and press the reset teries. button. Press the area marked “ ” with your Re-place the battery cover. finger and slide the cover to remove. ™...
  • Page 8: Power On/Off Button

    4-3. Setting the Current Time 1. When using for the first time, following replacement of batteries or pressing the reset button: ON/OFF 3 seconds CHECK TEST RUN later MODE ˚C CLOCK VANE STOP START NOT AVAILABLE NOT AVAILABLE MIN. ON/OFF ON/OFF All the LCD displays will light up for three seconds, then “AM 0:00 ”...
  • Page 9: Mode Button

    5. Operating Method ™ Each time signals are transmitted, the “ ” mark will appear. ™ When the signals are received by the air-conditioner, a sound confirming reception will be heard. Transmit again if no such sound is heard. 5-1. Starting Operation ™...
  • Page 10: Fan Button

    5-3. Changing the Fan Speed and Direction If the LCD displays are not on, press the POWER ON/OFF ON/OFF button. 1. To Change the Fan Speed ™ Press the FAN button and the fan speed will change. MODE For 4-stage speed: CLOCK VANE STOP...
  • Page 11: Setting The Timer

    5-4. Setting the Timer Stop Time Setting The air-conditioner stops operation when the pre-set time is reached. (The time can be set in steps of ten minutes.) e.g. To make the operation stop at 6:00 pm. ˚C 1. If the LCD displays are not on, press the POWER ON/OFF but- ton.
  • Page 12 Program Operation ™ Program operation can be used by carrying out Start Timer Setting and Stop Timer Setting one after the other. ™ In cases where the pre-set times for Stop Timer and Start Timer are the same, program operation can be used by pressing the STOP and START (TIMER SET) buttons one after the other.
  • Page 13: Test Run

    6. Test Run CHECK TEST RUN CHECK TEST RUN ˚C ˚C NOT AVAILABLE NOT AVAILABLE ON/OFF ON/OFF MODE CLOCK Reset VANE STOP START After refiling batteries. Press the reset button. MIN. 1 Turn on the main power to the unit. 2 Set the Nrm/Set selector switch (on the back of the controller) to «Set».
  • Page 14 Contents Page 1. Safety Precautions ................3 2. Checking the Contents of the Package ..........4 3. Name of Component ................5 4. Before Operation .................. 7 4-1. Setting the DIP-Switch ..............7 4-2. Inserting Batteries ................ 8 4-3. Setting the Current Time ............... 9 4-4.
  • Page 15: Centrally Controlled

    7. Centrally Controlled 1. In cases where local operation by wireless remote controller is prohibited. ™ When remote operation is prohibited due to centralized control, the prohibited operations cannot be performed using a wireless remote controller. • There are 3 types of remote operation that are prohibited, starting and stopping, operating mode and temperature setting.
  • Page 16 This product is designed and intended for use in a residential, commercial or light-industrial environment. The product at hand is based on the following EU regulations: • Electromagnetic Compatibility Directive 89/336/EEC HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310 TELEX J24532 CABLE MELCO TOKYO WT02966X01...

Table of Contents