Optional modules
Other options:
Town: Abingdon
Serial number: 12345678
Machine type: PT 8337
Load size: 13 kg
+ Button: Activated
Programme start: 11:30
Programme finished: 12:05
Total operating time: 0 h 35 min
Electrical energy: 12.5 kWh
Gas energy: 0 kWh
Steam energy: 0 kWh
Programme change: 2
(after making your selection and
pressing the rotary dial only the last 3 stops and starts will
be displayed.)
Programme fault: None
Area 1: Drying
Block1: Pre-drying
Process type: Residual moisture
Value: 15 %
Actual residual moisture: 15 %
Duration: 6 min
Max. exhaust temperature: 72 °C
Max. air intake temperature: 122 °C
Area1: Drying
Block2: Drying
Process type: Residual moisture
Value: 0 %
Actual residual moisture: 0 %
Duration: 6 min
Max. exhaust temperature: 78 °C
Max. air intake temperature: 138 °C
Area2: Cooling down
Block: Cooling down
Process type: Cooling down
Value: 50 %
Actual temperature: 50 °C
Duration: 3 min
Max. exhaust temperature: 52 °C
Max. air intake temperature: 95 °C
Residual moisture: -3 %
Delete data
Operating data module
Programme data
Delete data
[
After selecting Delete data the following message will
appear in the display:
Operating data module~ Delete data
Module: 21.02.2009
Total data: 12.07.2009
[
26
(only the last 3 faults are saved.)
The module menu option can be used to delete the
total data and programme data from the operating
data memory.
The total data option can only be used to delete the
total data from the operating data. The programme
data option can only be used to delete programme
data from the operating data.
After making your selection and pressing the rotary
dial you will be prompted to enter your password.
Password: _ _ _ _
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789
After keying in your password or inserting your
supervisor level key card in the reader the following
security prompt will appear in the display:
Delete operating data?
After pressing the S button the data will be deleted!

Peak load cut-out

Information on peak load cut-out
Switching the dryer off externally whilst a drying
process is running shortens the functional life of the
heat pump unit.
This dryer can be integrated into an energy
management system even though its very low energy
consumption makes a cut-out unnecessary.
Please note that if this tumble dryer is integrated into
a peak-load cut out management system, the unit
must not be switched off.
Information about operational status is provided via
the Miele peak load cut-out interface. Please note that
for control purposes the energy requirement of all
appliances which cannot be switched off must be
stored in the energy management system.
e
,
Accessing the internal wiring of the dryer by
A
bypassing the Miele peak load cut-out interface is
not permitted.
e
A