INSTALLATION
5.0 FIT REMAINING COMPONENTS
5.1 REFIT THE BURNER TRAY
5.2 FIT THE COAL BED
Fit the coal bed into the firebox as shown in Fig. 11
ensuring it is located behind the metal front rail.
5.3 FIT THE GLASS DOOR
Do this by inserting the top into the top clip of the
firebox and guiding the lower holes over the firebox
studs. Retain the glass door using the domed nuts
provided.
5.4 REFIT THE OUTER CASE
Fig. 10
This is done by placing it over the fire and refitting the 4
screws. Replace the control knob.
6.0 TEST FOR SPILLAGE
A spillage test must be made before the installed fire is
left with the user. Proceed as follows: after removal of
25mm
glass door mask (refer to Users Instructions).
Light the fire and leave on at full rate. Close all doors
and windows in the room and after the fire has been
alight for 5 minutes insert a lighted smoke match held in
a tube under the glass (Fig. 11) from the right or left
side. The tube is positioned against the side panel and
the smoke match must be in the gap at the bottom of
the glass and 25mm from the right (or left) side of the
door. If the smoke is drawn into the fire the installation is
satisfactory. note: the smoke will be drawn in 'lazily', as
the fire is fitted with a 'flue break' on the back. If the
smoke is not drawn into the fire leave it running for 10
more minutes and repeat the test. If the smoke is still
not drawn in check the sealing of the closure plate and if
this is satisfactory remove the spigot restrictor. If the
spigot restrictor has been removed re-fit the fire and
check again for spillage. If spillage persists DO NOT
LEAVE THE FIRE - SEEK EXPERT ADVICE AND
DISCONNECT THE FIRE.
Fig. 11
If there is a fan or fan operated appliance in a nearby
room then repeat the spillage test with the fan running
and inter-connecting doors between the fan and the fire
left open. If the fan and the fire are in the same room
then repeat the spillage test with the fan on and doors
and windows closed.
After the spillage testing has been performed re- fit the
door mask.