System battery replacement
If the server no longer automatically displays the correct date and time, then replace the battery that provides
power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
•
•
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
•
To remove the component:
Power down the server (on page 13).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do the following:
3.
Unlock the tower bezel (on page 14).
a.
Remove the tower bezel (on page 14).
b.
Remove the access panel (on page 15).
4.
Remove the air baffle (on page 17).
5.
Locate the battery on the system board
6.
Remove the battery.
7.
The computer contains an internal lithium manganese dioxide, a vanadium
("System board
components" on page 9).
System battery replacement 52
Need help?
Do you have a question about the ProLiant ML10 v2 and is the answer not in the manual?