Page 1
INSTALLATION & SERVICE INSTRUCTIONS B_1RREC / B_1RREC POU_1EC / POU_1RREC Series Coolers...
Page 2
ASSEMBLY AVAILABLE FROM THE MANUFACTURER OR ITS SERVICE AGENT -THIS APPLIANCE MUST BE EARTHED Contents: Technical Specification • Pre-Delivery Inspection • Filter Installation • Installing the OASIS green filter system • Cooler Installation • General Troubleshooting Guidelines • Accessing the Internal Chassis • Cleaning and Sanitizing Instructions •...
Page 7
B_1RREC / POU_1RREC Series Installation & Service Instructions General Information The B_1RREC & POU_1RREC Series coolers are designed for use with a supply of potable • water. The cooler should not be used with water supplies of unknown bacterial quality or those that are not already fit for human consumption.
Page 8
B_1RREC / POU_1RREC Series Installation & Service Instructions the ambient room temperature. The ambient water should be flushed after long periods of non use. Compressor The compressor uses the hydrofluorocarbon refrigerant R134a which is a non-Ozone depleting • substance with a Global Warming Potential of 1,300. The compressor is controlled by an electromechanical thermostat that controls the temperature of the water in the Reservoir.
Page 9
Oasis International supplies spare parts for all of its watercoolers. For European service, please • check the OASIS web-site at www.oasis.ie for full illustrated parts breakdowns that give full details of all replacement parts. For service from the United States, refer to the OASIS International web-site www.oasiscoolers.com Pre-Delivery Inspection: 1.
Page 10
This will prevent damage to the cabinet caused by coolers rubbing against one another in the back of the truck or van. Filter Installation: The B_1RREC & POU_1RREC series coolers contain a large filter compartment that can be directly accessed from the front of the unit. Accessing Filter Compartment Lift out and remove the drip tray •...
Page 11
Installing the OASIS green filter system [POU Only] • Both the OASIS EZ clip and EZ turn filters can be used as a 1 stage filter • Only the EZ clip filter can be used as a 2 stage filter if the CO2 bottle is fitted in the filter compartment •...
Page 12
B_1RREC / POU_1RREC Series Installation & Service Instructions Cooler Installation: The general installation guidelines below should be followed: The cooler must be located on a floor that is smooth, level and easily cleaned. • Do not locate the cooler in direct sunlight.
Page 13
B_1RREC / POU_1RREC Series Installation & Service Instructions 11. When fitted to a cooler the height from the floor to the top of the bottle should not exceed 1.5 metres. 12. Ensure that the appliance is positioned to give access to the plug after the unit is installed.
Page 14
EPWDA member company must receive this training. The purpose of this training program is to provide an overview of POU systems offered by OASIS and an introduction to the basic guidelines that should be followed when installing an OASIS water cooler onto an existing mains water system.
Page 15
All fittings and piping used to attach the water cooler to the water supply must be approved to the relevant local standards. These fittings can be purchased from Oasis International or Oasis Europe can refer you to reputable suppliers of Point-of-Use parts in your market place.
Page 16
Installation & Service Instructions Connecting POU cooler to water supply All OASIS POU water coolers are supplied with a push-fit connector that should be used to connect the cooler to the water supply. Oasis International recommends that these guidelines should be followed when installing the cooler: •...
Page 17
B_1RREC / POU_1RREC Series Installation & Service Instructions CAUTION: A PRESSURE REGULATOR, SUCH AS A SLOW FLOW REGULATOR, MUST BE INSTALLED IN FRONT OF THE WATER INLET IF THE WATER PRESSURE (INCLUDING ANY SPIKES) COULD EXCEED 7 BAR (700kPa) 15. On models with a hot tank, turn on the hot tank by depressing the switch toward the “ON”...
Page 18
B_1RREC / POU_1RREC Series Installation & Service Instructions 11. Allow the cooler to operate for about 30 minutes for chilled and hot water dispensing CAUTION: WATER FROM THE HOT FAUCET CAN SCALD TO DISCONTINUE USE OF POU WATER COOLER 1. Disconnect the power supply cord from the power supply.
Page 19
B_1RREC / POU_1RREC Series Installation & Service Instructions 5. Remove the faucet cover as follows: o Press up the bottom of the cover, clearing the bottom hooks of the mounting holes o Drop the cover to unhook the upper clips o Remove the cove forward over the faucet levers 6.
Page 20
B_1RREC / POU_1RREC Series Installation & Service Instructions General Troubleshooting Guidelines: • No water flow when any dispense button is pressed: o Ensure that the unit is connected to the electrical supply, and that power is going to the unit.
Page 21
B_1RREC / POU_1RREC Series Installation & Service Instructions o Ensure all wires are connected to the CO2 electronic board o Ensure pump is running when button is pressed o Water within cooling system is frozen. Refer to the notes for “Water flows from the hot system, and no water flows from cold system”...
Page 22
B_1RREC / POU_1RREC Series Installation & Service Instructions Cleaning and Sanitizing Instructions: Cleaning Procedure Water coolers need to be cleaned periodically to prevent mineral build-up inside the heating tank. The frequency of cleaning is determined by the quantity of minerals in the water and the amount of water used.
Need help?
Do you have a question about the POU_1RREC Series and is the answer not in the manual?
Questions and answers