Download Print this page

Tools Needed For Installation; Parts Supplied For Installation - Whirlpool 3402328 Installation Instructions Manual

Advertisement

Tools needed for
installation:
adjustable
wrench
dew
glasses
utility knife
level
Phillips screwdriver
pliers
Bat-blade
duct tape
screwdriver
gloves
Parts supplied for
installation:
2 slide protectors
8 screws
2 slide extensions
2, SO-minute cams
2 bolt and washer
2,60-minute
cams
assemblies
4.314" wood
screws
Parts owner must
supply:
1 control
panel lock and key
2 coin vaults and keys (E.S.D. vault must
have projecting
lock.)
2 coin-slide
mechanisms
(vertical
8)
Parts may be ordered
from
Greenwald
Industries, Inc. or
Equipment
Systems and Devices,
Inc.
l
Greenwald
Industries, Inc.
1340 Metropolitan
Avenue
Brooklyn, NY 11237
telephone
(7 18) 82 l-9000 or
toll free (800) 221-0982
fax(718)417-7412
l
Equipment
Systems and
Devices,
Inc.
270 New Jersey Dr.
Fort Washington,
PA 19034
telephone
(215) 628-0860 or
toll free (800) 523- 1510
fax (215) 643-4623
l
Monarch
P.O. Box 427
105-l 15 East Fourth St.
Covington,
KY 41011
Gas supply
reauhements
Fire Hazard
Dryers must be connected
to a
regulated gas supply.
Failure to do so could result In hlgh-
pressure gas release, resulting In a
fire or exploslon.
Have L.P. gas checked by a
quallfled person bdore lnstalllng the
dryer. The L.P. gas supply must not
exceed 13 Inches water column
pressure.
New, flexible tublng should be used.
Reuslng old, flexible tublng mlght
result In possible gas leaks.
Failure to follow these lnstructlons
could result In flre or exploslon.
OBSERVE ALL GOVERNING CODES
AND ORDINANCES.
A
n
This installation
must conform
with American
National
Standard,
National
Fuel Gas Code ANSI Z223.1-
latest edition,*
and all local codes
and ordinances.
B
n
The desian of this drver has
been certified
by the American
Gas
Association
for use at altitudes
up to
3000 m (10.000 feet) above
sea level
at the B.T.U. rating indicated
on the
model/serial
rating plate.
Burner input
adjustments
are not required
when
the dryer is operated
up to this
elevation.
When installed
above
3000 m (10,000
feet), a four percent
(4%) reduction
of
the burner B.T.U. rating shown on the
model/serial
rating plate is required
for each 300 m (1 ,ooO foot) increase
in elevation,
For assistance
when
converting
to other gas types and/or
installing above
3000 m (10,000 feet)
elevation,
contact
your local service
company.
C
n
Check that dryers are
equipped
with the correct
burner for
the particular
type of gas used.
Burner information
will be found on
the rating plate in door well of the
appliance.
If thls information
does not
agree
with the type of gas available,
see your dealer.
D
n
These dryers
are shipped
for use
with NATURAL GAS.
They are certified
by
the American
Gas
Association
for
manufactured,
mixed and L.P.
(propane
and butane)
gases with
appropriate
conversion.
No attempt
shall be made
to convert
the
appliance
from the gas specified
on
the model/serial
rating plate for use
with a different
gas without
consulting
the serving gas suppller.
Converslon
must be done by a quallfled service
technlclan.
Gas converslon klt part
numbers are llsted on the gas valve
burner base.
E
n
Provide a
rlgld gas supply line
of l/2-inch
IPS pipe to ihe dryer's
location.
If the total length of the
supply line is more than 6.1 m
(20 feet), larger pipe will be needed.
For L.P. gas usage, 3/8-inch,
approved
copper
tubing
may be
used. Pipe-ioint
comDounds
suitable
fge
with L.P. gas should be used
F
n
If local codes and ordinances
permit, it is recommended
that new
flexible metal tubing,
design-certified
by the American
Gas Association.
be
used for connecting
the dryers to the
gas supply line. (The gas feed pipe.
which extends
through
the lower rear
of each dryer, is provided
with
3/8-inch
male plpe thread.)
G
w The SUDDIV line shall be
equipped
with a manual
shutoff
valve. This valve should be located
in
the same room as the dryers and
should be in a location
that allows
ease of opening
and closing. Do Not
block access to shutoff valve.
H.
connec
main gas supply line, a
combination
of fittings must be
used to obtaln
an in-line connection
to the dryers.
Copies of the standards
listed above
may
be obtained
from:
*American
Gas Association
11515 Wilson Boulevard
Arlington,
Virginla
22209
Page 3

Advertisement

loading