Parts Supplied For Installation; Power Supply Cord - Whirlpool 3397617 Installation Instructions Manual

Advertisement

Available languages

Available languages

Tools and
Electrical
materials needed
requirements
for installation:
l
duct tape
l/4" socket
wrench
or nut
driver (shown)
1" socket
wrench
safety glasses
Parts supplied
for installation:
Remove
parts from packages.
Check
that all parts were included.
4 leveling
legs
literature
package
Electrical
Shock Hazard
Electrical
ground
is required
on this
appliance.
Do Not modify
the power
supply
cord plug. If it does not fit the outlet,
have a proper
outlet installed
by a
qualified
electrician.
Do Not have a fuse in the neutral or
grounding
circuit.
A fuse in the
neutral or grounding
circuit
could
result in an electrical
shock.
Do Not use an extension
cord with
this appliance.
Check
with a qualified
electrician
to
be sure this appliance
is properly
grounded.
Do Not connect
plug end of power
supply
cord into a live receptacle
before
connecting
power supply
cord to dryer terminal
block.
Do Not reuse old power
supply
cord.
Failure to follow these instructions
could result in death or serious
injury.
If codes
permit
and a separate
grounding
wire is used, it is
recommended
that a qualified
electrician
determine
that the
grounding
path is adequate.
A three-wire
or four-wire,
single phase
120/240-volt,
60-Hz, AC-only,
electrical
supply (or three-wire
or four-wire
120/208-volt
if specified
on serial/rating
plate)
is required
on a separate
30-ampere
circuit,
fused on both sides
of the line. A time-delay
fuse or circuit
breaker
is recommended.
wirina
w
A wiring diagram
the console
or on
back panel
of
dryer.
It is the personal
responsibility
and
obligation
of the customer
to contact
a qualified
electrician
to assure that
the electrical
installation
is adequate
and is in conformance
with the
National
Electrical
Code,
ANSVNFPA
70 -
latest* and all local codes
and
ordinances.
Copies
of the standards
listed above
may
be obtained
from:
*National
Fire Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
02269
Important:
Observe
all governing
codes and ordinances.
Power supply cord
Use a new 30-amp power supply
cord.
Local codes
may permit the use of a
U.L.-listed,
120/240-volt
minimum,
30-ampere,
dryer power
supply cord kit
(pigtail).
Power supply cord should be
Type SRD or SRDT and be at least four
feet (1.2 m) long. The wires that
connect
to the dryer must end with
ring terminals
or spade
terminals
with
upturned
ends.
A 3/4", U.L.-listed strain
relief must be installed
where the
power
supply cord connects
to the
dryer (see Figures 1 and 2).
upturned
ends
rina
to this conductor.
terSinals
314" U.L.-listed /
NEUTRAL
strain relief
(white or center)
Three-wire power supply cord
NEMA lo-30P
Figure 1
314" U.L.-listed
strain relief
\
NEUTRAL
(white),
F
NEUTRAL
grounding
prong
(green)
ring
\
terminals
Four-wire power supply cord
(Mobile home or
other four-wire installations)
NEMA 14-30P
Figure 2
Page 3