[Cm06] Misc. Trunk Number Assignment - NEC NEAX 2000 IVS Command Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

COMMAND CODE
06
1.
FUNCTION:
This command assigns Miscellaneous Trunk Numbers to each card.
2.
PRECAUTION:
This command requires a system reset after setting the data.
3.
ASSIGNMENT PROCEDURE:
+ 06YY +
ST
4.
DATA TABLE:
YY
MISC. TRUNK NO.
04
00 ~ 15 MF Receiver /911 Sender
Trunk 00 – 15
07
0 ~ 3
CCH (Common Channel Han-
dler) Number 0 ~ 3
08
0 ~ 4
DCH (D Channel Handler)
Number 0 ~ 4
09
00 ~ 11 ICH (ISDN Channel Handler)
Number 00 ~ 11
10
XX XX Slot Number (04 – 15) of PN-
SC03
+
D Channel Block Number
(00 – 03)
[CM06]
Misc. Trunk Number Assignment
TITLE:
MISC. TRUNK NUMBER ASSIGNMENT
1ST DATA
+
+
DE
(1-4 digits)
AP NUMBER + CIRCUIT NUMBER
XXX
XX
XX
XX
XXXX XXXX
ND-45669 (E)
2ND DATA
+
+
DE
(2-4 digits)
XX X
Circuit Number
(0 – 3)
Slot Number
(04 – 15) assigned by
CM05
XX
Slot Number
(04 – 15) of
PN-SC00
XX
Slot Number
(04 – 15) of
PN-SC01
XX
Slot Number
(04 – 15) of
PN-SC02/PN-SC03
LEN of PN-2CSI
(0000, 0004-0504,
0508)
EXE
RELATED
COMMAND
CM05
CM05
CM30
CM35
CMA7, CMA8
CM05
CM35 YY = 93
CM05
CM05
CM06
CHAPTER 3
Page 69
Revision 2.0

Advertisement

Table of Contents
loading

Table of Contents