TECHNICAL MANUAL
MMC: 204
DESCRIPTION:
Determines whether the common bell relay contact has an interrupted or
continuous closure when activated. If interrupted is chosen, the relay follows an
internal C.O. ring pattern of one second closed followed by three seconds open. By
default the common bell relay pair is assigned.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor
SPEAKER
Used to store data and advance to next MMC
ACTION
1. Press TRANSFER 204
Display shows current setting
2. Dial common bell number
3. Dial 0 for continuous or 1 for interrupted
operation
OR
Use UP or DOWN to scroll through options
Press RIGHT soft key to return to step 2.
4. Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to
next MMC.
DEFAULT DATA:
CONTINUOUS
RELATED ITEMS:
MMC 203 ASSIGN UA DEVICE
MMC 218 RELAY TYPE
MMC 601 ASSIGN STATION GROUP
MMC 724 MISC NUM PLAN
COMMON BELL CONTROL
DISPLAY
[204] COM. BELL
CONTINUOUS
[363] COM. BELL
CONTINUOUS
[363] COM. BELL
INTERRUPTED