Tru64 Unix Environments - HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Installation Manual

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Note:

Tru64 UNIX environments

HP StorageWorks 1500 Modular Smart Array Installation Guide
d. For each HBA, verify that the following options are specified: load
ql2x00.ham slot=x/luns/allpaths/portnames, where x
represents the slot number.
The Native MPIO solution can co-exist with HP Secure Path for NetWare.
If the MSA is upgraded to 6.86or later active/active firmware, and, if you want
to remove the Secure Path for NetWare driver, do the following:
a. Follow the removal instructions provided in the Secure Path user
documents.
b. From the console, enter edit c:\NWSERVER\STARTUP.NCF.
c. Comment out the following entry: #load hpqsp.cdm
d. Enter edit sys:\system\autoexec.ncf
e. Comment out the following entries:
LOAD hpqspagt.nlm
LOAD hpqspahw.nlm
Single-controller configurations and active/passive firmware are not
supported; the MSA must be upgraded to dual-controllers running
active/active firmware.
The AlphaServer must have Tru64 UNIX v5.1.b PK4 (or later) installed.
The AlphaServer must be configured in a SAN switch zone with the MSA.
After installing the MSA, be sure to set the host mode for each Tru64 UNIX
connection to tru64.
For information on upgrading the MSA to active/active, see the migration
instructions for Tru64 UNIX environments, available on the Technical
documents page of the MSA1500 website:
http://www.hp.com/go/msa1500cs.
Configuration Procedures - Other Environments