Bosch PST 6101.321 Technical Information page 76

Timer and i/o level
Table of Contents

Advertisement

<Weld/No weld>
1070 080 056-101 (99.09) GB
PST 6101.321 / PSI 6101.321
If the sum of all firing settings (logical AND operation) is switched on when a program
number is selected, the <Weld/No weld> signal ON is output.
-
<Weld/No weld> signal ON:
All firing settings for the selected program of the timer are active. The [Sequence]
is performed with welding current.
-
<Weld/No weld> signal OFF:
One of the firing settings is inactive, or no program number has been selected. The
[Sequence] is performed without welding current.
If firing has been switched off externally, a timer status message is displayed at the
programming terminal.
Firing settings:
-
<Weld/No weld external> signal ON
-
Programming of weld/no weld internal for all programs in the menu Programming -
Basic Setup - Sequence-Setup.
-
Programming of program-related weld/no weld for one program in the menu Pro-
gramming - Basic Setup - Sequence-Setup.
For all timers
Weld external
on
internal
off
off
off
off
on
on
on
on
[1] Caution: Program-related firing may be active for other programs
Figure 26: Firing settings
Program-related
firing
Weld
off
off
off
on
on
off
on
on
off
off
off
on
on
off
on
on
Electrical connection
Program-related
sequence
Sequence without
welding current
Sequence without
welding current
Sequence without
welding current
Sequence without
welding current
Sequence without
welding current
Sequence without
welding current
Sequence without
[1] welding current
Sequence w i t h
welding current
7-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psi 6101.321

Table of Contents