Bosch PST 6101.321 Technical Information page 58

Timer and i/o level
Table of Contents

Advertisement

1070 080 056-101 (99.09) GB
PST 6101.321 / PSI 6101.321
-
The Stop function is ensured by means of a floating contact which is to be con-
nected to terminals X4/3 and X4/4.
-
Opening the stop contact will interrupt:
-
the firing
-
the power supply to the parallel inputs and outputs
(only outputs for PSI 6101.321 / PST 6101.321)
-
the power supply to the external unit.
PSI 6101.321 / PST 6101.321
X output
A
0 V
X10
+ 24 VDC
24 V
* 0 V
0 V
+ 24 VDC
24 V
* 0 V
0 V
Jumper between X10/0 V -> X4/2
Jumper between X10/24 V -> X4/1
* reference potential for parallel inputs/outputs (not with these timer types)
Figure 14: External power supply by two power supply units
Configuration D:
Power supply for firing and parallel inputs and outputs
by an external 24 VDC power supply [1] (with PSI
6101.321 / PST 6101.321 only outputs).
Power supply to weld timer logics, the external device
and the serial inputs and outputs by a second external
power supply unit [2].
*1 stop circuit:
floating contact
24 VDC / max. 3A
X4
+ 24 VDC
1
2
3
4
5
+ 24 VDC
6
D
7
D
8
9
+ 24 VDC
10
D
11
D
12
+ 24 V fan
13
14
X5
+ 24 V
1
2
D
Electrical connection
Power supply
+
load:
0 V
*1
0 V
Power supply
[2]
unit
+
-
0 V
0 V fan
0 V
[1]
unit
-
7-15