Xlr3 Connector Assy; Capsule Suspension, Microphone Frame - Sony C-100 Service Manual

Condenser microphone
Hide thumbs Also See for C-100:
Table of Contents

Advertisement

C-100

2-11. XLR3 CONNECTOR ASSY

1 screw
(Supplied with XLR3 connector assy)
Note 1: This screw is fixed with bond.
Note 2: When tightening screw, tighten
5 XLR3 connector assy
Note 3: When installing the XLR3 connector
assy, align the slit and protrusion.
connector side

2-12. CAPSULE SUSPENSION, MICROPHONE FRAME

3 cushion
(conductive)
(See Fig. H)
connector side
1 screw (PSW3
5)
Note: When tightening screw, tighten
the below torque value.
tightening torque:
cushion
(conductive)
Affix the end of the cushion
(conductive) to this area.
14
When installing this screw, first apply
bond (LOCTITE 243 or equivalent) to it.
the below torque value.
tightening torque:
4 ferrite bead
2 Remove the connector block
protrusion
in the direction of the arrow.
2 capsule suspension
capsule side
4 microphone frame
3 cushion
(conductive)
(See Fig. H)
cushion
(conductive)
Affix the end of the cushion
(conductive) to this area.
slit
3 ferrite bead
When installing the capsule suspension, align it with
the hole of the microphone frame.
short
long
hole
microphone frame
capsule side
wide
narrow