3. Installation

3.1 Installation siter

CAUTION
CAUTION
(1) Locate indoors only in industrial environment area.
(2) Avoid exposure to the direct sun light or the rain or water
spray.
(3) Range of temperature of the ambient air:
(a) during welding:10 to 40 deg-C,
(b) after transport and storage:-20 to 55 deg-C
(4) Humid:
(a) up to 50% at 40deg-C,
(b) up to 90% at 20deg-C
(5) Altitude above sea level: up to 1000 m.
(6) Installing distance to maintain adequate airflow:
(a) 20 cm or more from any wall,
(b) 30 cm or more between power sources installed side-
by-side.
(7) Base of the welding power source inclined:max. 10deg.
(8) Avoid wind to the arc (provide windshields.)
(9) Free from abnormal amounts of dust, acid, corrosive
gases or substances etc. other than those generated by
the welding process (Especially, avoid where the metallic
substance may get into the power source.)

3.2 Power supply equipment

CAUTION
Input voltage
Input current
Input protective devices
(Breaker, fuse etc.)
Cable cross section area
for input cable and ground wire
Note
• This Class A equipment is not intended for use in resi-
dential locations where the electrical power is provided
by the public low-voltage supply system. There can be
potential difficulties in ensuring electromagnetic compati-
bility in those locations, due to conducted as well as radi-
ated radio-frequency disturbances.
OMCTT5639E09
This product is designed for indoor use only.
Do not install it in any places subject to rain or water spray.
Do not use this product in a vertical position (i.e.: with its control panel side up).
Using it in the vertical position may reduce its cooling effect, and cause any
troubles like equipment burnout, etc. Therefore, make sure to use it in the
horizontal position (in the proper position).
Observe the following to prevent burnout, destruction of parts and
unstable arc.
200 VAC
32 A
Type and capacity to be applied should conform to all national and
local codes.
Type and size of cables to be applied should conform to all national
and local codes.
20cm
30cm or more
Note
When the product, which is installed on the floor, is too
low to operate, customers are required to prepare a
table to mount it. (And, in that case, provide such a table
with a flange, etc. so that the product does not slip down from
the table.)
• This equipment does not comply with IEC 61000-3-12. If
it is connected to a public low voltage system, it is the
responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network
operator, that the equipment may be connected.
Installation
11