6.2.3.11

DRIVE-CLiQ interfaces X400, X401, X402

Table 6- 33
Connector
Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Article number: 6SL3066-4CA00-0AA0
6.2.3.12

Test points for 1 mm test probes

On the connectors X41, X46, X47 and X49 you will find test points for 1 mm test probes on
the sides, see ① in the following figure.
Figure 6-16
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
DRIVE-CLiQ interfaces X400, X401, X402
PIN
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Test points for 1 mm test probes
Motor Modules
6.2 Motor Modules Chassis-2
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
24 V power supply
Electronics ground