Complete Configuration File - Siemens SINUMERIK 840D sl Commissioning Manual

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

14.4.5

Complete configuration file

1. Open the file from one of the directories in the editor.
2. Enter the name of the new alarm attribute file in the <OEM_DataBase_xx...> tag, see
Inserting further alarm attribute files
If you add further files with user-specific alarm attributes to the configuration file, you must
add a corresponding number of names. The list can be extended to any length.
1. Copy the contents of the <OEM_DataBase_01> file;
2. Insert the line between the tags <DataBases> and </DataBases>.
3. Increment the number of the last existing "OEM_DataBase_xx" tag by one.
4. Insert the name of the corresponding alarm attribute file, but without the file extension
Note
The "DataBase_01" tag is reserved for Siemens
Example
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
example "muster_slaedatabase".
In the example: <OEM_DataBase_01 type="QString value="muster_slaedatabase"/>.
".xml".
Configuring alarms
14.4 Changing alarm colors
139