13. Decommissioning

13.1

Temporary shutdown

In the event of lengthy periods of non-use:
Unplug the electrical connection.
13.2

Change of location

If the WBE 260 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
The WBE 260 is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
Secure WBE 260 back to pallet with 3 screws.
13.3

Disposal and scrapping

13.3.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
13.3.2

WBE 260 and accessories

1. Disconnect the WBE 260 from the mains and detach
the power cord.
2. Dismantle the WBE 260 and sort out and dispose of
the different materials in accordance with the appli-
cable regulations.
WBE 260, accessories and packaging should
be sorted for environmental-friendly recycling.
Do not dispose WBE 260 into household
waste.
Only for EC countries:
The WBE 260 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of WBE 260 prevents en-
vironmental pollution and possible health
hazards.
Decommissioning | Start Line WBE 260 | 41

14. Technical parameters

14.1

WBE 260

Function
rotational speed
Balancing precision
Noise
Motor power
Voltage
Degree of protection
14.2

Size and weight

Function
Size of packaging
(length x width x height)
Net weight
14.3

Operating range

Function
Rim width
Rim diameter
Max. wheel diameter
Max. wheel weight
14.4

Temperatures and operating range

Function
Operating Temperature
Storage Temperature
Temperature gradient
Relative operating humidity
(25 °C, 24 hrs)
Relative humidity gradient
Installation height
Transportation height
en
Specification
910 rpm 50 Hz
1100 rpm 60 Hz
± 1 g
Under 70 dB
0.37 kW
230 V/1 P/50-60 Hz
IP22
Specification
855×705×1085 mm
145 kg
Specification
1.5 inches - 20 inches
12 inches - 26 inches
1050 mm
65 kg
Specification
+5 °C \ +40 °C
-20 °C \ + 60 °C
20 °C / h
<75 % \ max 90 %
10 %
-200 m. \ 2.200 m.
-200 m. \ 12.000 m.
|
1 695 600 539
2016-07-22