Siemens SINUMERIK 840D sl Function Manual page 117

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data backup
The protection-zone definitions are saved in the following files:
File
_N_INITIAL_INI
_N_COMPLETE_PRO
_N_CHAN_PRO
2.2.5
Activation and deactivation of protection zones
General
The activation status of a protection zone is:
• Preactivated
• Preactivated with conditional stop
• Enabled
• Deactivated
A protection zone is monitored for violation only when it is activated.
Activation
The activation of a protection zone can take place through:
• Part program instruction
• Automatically after the control powers up
• PLC user program
The preactivation, deactivation and activation of all protection zones always takes place
channel-specifically. A protection zone can also be active in multiple channels
simultaneously (application example: Double-slide single-spindle machine with one quill and
two machining slides.
Protection zones are activated immediately after the runup of the control, if the
corresponding system variable $SN_PA_ACTIV_IMMED[n] or. $SC_PA_ACTIV_IMMED[n]
has been set.
Note
Machine-related protection zones are activated after the runup of the control in all channels.
An activated protection zone is only taken into account after the successful referencing of all
participating geometry axes.
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
For activation through the PLC user program, the protection zone must be first
preactivated via a part program.
Blocks
All data blocks of the protection zones
All data blocks of the protection zones
All data blocks of the channelspecific protection zones
Detailed description
2.2 Protection zones
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents