Technical Data - Siemens SINAMICS S120 Equipment Manual

Water-cooled chassis power units for common cooling circuits
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
7.1 Sine-wave filter
7.1.4

Technical data

Table 7- 2
Technical data of sine-wave filters 380 V ... 480 V 3 AC
Article number
Suitable for Power Module
Suitable for Motor Module
Rated current (unit rating) of the
Power Modules or Motor Mod-
ules with sine-wave filter
at pulse frequency of 4 kHz
Rated current
Maximum output frequency
Power loss
- At 50 Hz
- At 150 Hz
Connections
- to the Power Module or Motor
Module
- load
Max. permissible cable length
between sine-wave filter and
motor
Degree of protection
Dimensions
Width
Height
Depth
Weight
184
6SL3000-
2CE32-3AA0
6SL3315-
1TE32-1AAx
6SL3325-
1TE32-1AAx
170 A (90 kW)
A
225
Hz
150
kW
0.35
kW
0.6
m
IP00
mm
620
mm
300
mm
320
kg
124
2CE32-3AA0
2CE32-8AA0
1TE32-6AAx
1TE33-1AAx
1TE32-6AAx
1TE33-1AAx
215 A (110 kW)
270 A (132 kW)
225
276
150
150
0.35
0.6
0.69
M10 connecting lugs
M10 connecting lugs
300 (shielded)
450 (unshielded)
IP00
IP00
620
620
300
300
320
320
124
127
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
2CE34-1AA0
1TE35-0AAx
1TE35-0AAx
380 A (200 kW)
408
150
0.4
0.38
0.7
IP00
620
370
360
198

Advertisement

Table of Contents
loading

Table of Contents