4.1.3

Additional modules

4.1.3.1

Control Supply Module

Table 4- 33
Control Supply Module – description of the LEDs
LED
Color
State
READY
off
Green
Continuous
light
DC LINK
off
Orange
Continuous
light
Red
Continuous
light
4.1.3.2

Sensor Module Cabinet SMC10 / SMC20

Table 4- 34
Sensor Module Cabinet 10/20 (SMC10/SMC20) – description of the LEDs
LED
Color
RDY
READY
Green
Orange
Red
Green/red Flashing
Green/
orange
or
Red/
orange
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
Component is ready to operate.
Electronic power supply is missing or outside permissible
tolerance range.
DC link voltage within permissible tolerance range.
DC link voltage outside permissible tolerance range.
State
Description, cause
off
Electronic power supply is missing or outside permissible
tolerance range.
Continu-
The component is ready for operation and cyclic DRIVE-
ous light
CLiQ communication is taking place.
Continu-
DRIVE-CLiQ communication is being established.
ous light
Continu-
At least one fault is present in this component.
ous light
Note:
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
Firmware is being downloaded.
light 0.5
Hz
Flashing
Firmware download is complete. Wait for POWER ON
light 2 Hz
Flashing
Component recognition via LED is activated (p0144).
light
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.
Diagnostics
4.1 Diagnostics via LEDs
Remedy
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
327