9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Header Type
Specifies the header of the SIP message in which the caller information is stored.
Value Range
From Header, P-Preferred-Identity Header
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
From Header—User Part
Specifies the value to be stored in the username part of the SIP-URI of the From header.
Value Range
User Name, Authentication ID, PBX-CLIP
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
From Header—SIP-URI
Specifies the complete SIP-URI address of the From header. The configuration in From Header—User Part
will be invalid if this parameter is set.
Value Range
Max. 100 characters
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
P-Preferred-Identity Header—User Part
Specifies the value to be stored in the username part of the SIP-URI of the P-Preferred-Identity header.
Value Range
User Name, Authentication ID, PBX-CLIP
284