24.4 UM Configuration—[5-4] System Parameters—Parameters
Maximum Call Duration (0-60 min)
Specifies the maximum duration of calls. If the system detects no DTMF signals for the specified amount of
time, it terminates the call. Calls will not be terminated while playing or recording messages. If this setting is
set to "0", calls will not be terminated.
Value Range
0–60 min
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Transfer to Outside
These parameters determine how the system will transfer calls to a trunk via the following features: Call
Transfer Service, Custom Service, Personal Custom Service, Caller ID Callback, Call-through Service.
Outside Transfer Sequence—Call Transfer to Outside Sequence (Up to 16
digits / [0-9 * # D F R T , ; N])
Specifies the sequence the system uses to transfer calls to trunks.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
0–9,
, #: Dial Code
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Feature Guide References
3.2.1.7 Call Transfer to Outside
Outside Transfer Sequence—EFA Transfer Sequence (Up to 16 digits / [0-9 * #
D F R T , ; N A])
Specifies the sequence the system uses to transfer calls to trunks using EFA (External Feature Access). This
setting should match the settings of the PBX.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)