Table 20-8. Server Status Screen (continued)
Severity
Critical
Critical
Warning
Critical
Critical
Critical
Critical
Critical
Critical
Non-Recoverable CPU Protocol Err:
Message
System Board OS Watchdog:
Watchdog sensor for System
Board, power cycle was asserted
System Board SEL: Event Log
sensor for System Board, log full
was asserted
ECC Corr Err: Memory sensor,
correctable ECC
( <DIMM Location> ) was
asserted
ECC Uncorr Err: Memory sensor,
uncorrectable ECC
( <DIMM Location> ) was
asserted
I/O Channel Chk: Critical Event
sensor, I/O channel check NMI
was asserted
PCI Parity Err: Critical Event
sensor, PCI PERR was asserted
PCI System Err: Critical Event
sensor, PCI SERR
( <Slot number or PCI Device
ID>) was asserted
SBE Log Disabled: Event Log
sensor, correctable memory error
logging disabled was asserted
Logging Disabled: Event Log
sensor, all event logging disabled
was asserted
Processor sensor, transition to
non-recoverable was asserted
Recovering and Troubleshooting the Managed System
Cause
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
power cycle
The SEL device detects that
only one entry can be added to
the SEL before it is full
Correctable ECC errors
reached a critical rate
An uncorrectable ECC error
was detected
A critical interrupt is generated
in the I/O Channel
Parity error was detected on the
PCI bus
PCI error detected by device
Single bit error logging is
disabled when too many SBE
get logged
All error logging is disabled
The processor protocol entered
a non-recoverable state
319