Explanation Of The List Of Faults And Alarms - Siemens G130 List Manual

Hide thumbs Also See for G130:
Table of Contents

Advertisement

4.1.2

Explanation of the list of faults and alarms

The data in the following example has been chosen at random. The information listed below is
the maximum amount of information that a description can contain. Some of the information is
optional.
The "List of faults and alarms" (Page 1369) has the following layout:
- - - - - - - - - - - - Start of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx (F, N)
Fault location (optional): Name
Message value:
Component number: %1, fault cause: %2
Message class:
Text of the message class (number according to PROFIdrive)
Drive object:
List of objects.
Component:
Control Unit (CU)
Reaction:
NONE
Acknowledgement:
NONE
Cause:
Description of possible causes.
Fault value (r0949, interpret format): or alarm value (r2124, interpret format): (optional)
Information about fault or alarm values (optional).
Remedy:
Description of possible remedies.
Response to F:
A_INFEED: OFF2 (OFF1, NONE)
SERVO: NONE (OFF1, OFF2, OFF3)
VECTOR: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY (POWER ON)
Response upon N:
NONE
Acknowl. upon N:
NONE
- - - - - - - - - - - - End of example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axxxxx
Alarm xxxxx
Axxxxx (F, N)
Alarm xxxxx (message type can be changed to F or N)
Fxxxxx
Fault xxxxx
Fxxxxx (A, N)
Fault xxxxx (report type can be changed to A or N)
Nxxxxx
No message
Nxxxxx (A)
No message (message type can be changed to A)
Cxxxxx
Safety message (separate message buffer)
A message comprises a letter followed by the relevant number.
The meaning of the letters is as follows:
• A means "Alarm"
• F means "Fault"
• N means "No message" or "Internal message"
• C means "Safety message"
The optional brackets indicate whether the type specified for this message can be changed
and which message types can be adjusted via parameters (p2118, p2119).
Information about reaction and acknowledgment is specified independently for a message with
adjustable message type (e.g. reaction to F, acknowledgment to F).
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
4.1 Overview of faults and alarms
Propagation:
GLOBAL
4 Faults and alarms
1361